23-23
Catalyst 6500 Series Switch and Cisco 7600 Series Router Firewall Services Module Configuration Guide using ASDM
OL-20748-01
Chapter 23 Configuring Management Access
AAA for System Administrators
Table 23-1
describes the
show curpriv
command output.
Recovering from a Lockout
In some circumstances, when you turn on command authorization or CLI authentication, you can be
locked out of the FWSM CLI. You can usually recover access by restarting the FWSM. However, if you
already saved your configuration, you might be locked out.
Table 23-2
lists the common lockout
conditions and how you might recover from them.
Table 23-1
show curpriv Display Description
Field
Description
Username
Username. If you are logged in as the default user, the name is enable_1 (user
EXEC) or enable_15 (privileged EXEC).
Current privilege level Level from 0 to 15. Unless you configure local command authorization and
assign commands to intermediate privilege levels, levels 0 and 15 are the only
levels that are used.
Current Mode/s
Shows the access modes:
•
P_UNPR—User EXEC mode (levels 0 and 1)
•
P_PRIV—Privileged EXEC mode (levels 2 to 15)
•
P_CONF—Configuration mode
Table 23-2
CLI Authentication and Command Authorization Lockout Scenarios
Feature
Lockout Condition Description
Workaround: Single Mode
Workaround: Multiple Mode
Local CLI
authentication
No users in the
local database
If you have no users in
the local database, you
cannot log in, and you
cannot add any users.
Log in and reset the
passwords and
aaa
commands.
Session in to the FWSM
from the switch. From the
system execution space, you
can change to the context
and add a user.
command
authorization
CLI
authentication
RADIUS CLI
authentication
Server down or
unreachable and
you do not have
the fallback
method
configured
If the server is
unreachable, then you
cannot log in or enter
any commands.
1.
Log in and reset the
passwords and AAA
commands.
2.
Configure the local
database as a fallback
method so you do not
get locked out when the
server is down.
1.
If the server is
unreachable because the
network configuration
is incorrect on the
FWSM, session in to the
FWSM from the switch.
From the system
execution space, you
can change to the
context and reconfigure
your network settings.
2.
Configure the local
database as a fallback
method so you do not
get locked out when the
server is down.
Содержание 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion