7.5.10 Night mode
If there is a need to reduce the maximum value of electric and/or noise absorption of the compressor, e.g. in
night-time operation, it is possible to activate the Night mode function using the relative external contact (Terminal
28-29) or Low tariff/Night mode button of the Remote controller.
If Night mode function starts, according to a time band, the maximum frequency will be decreased to the value
selected on Par4111 in the ON time by time band setting. Otherwise it will operate in normal mode.
Note1: Par5128 (Night mode) and Par5130 (Low tariff) are automatically synchronized to same value.
If Par5128 is changed to 1 (enable), then Par5130 will be also changed to 1 (enable).
Note2: During Night mode with Night mode contact ON, if Par5128 is changed to 0, the HP unit will continue to
operate in Night mode.
During Night mode by the Remote controller button, if Par5128 is changed to 1, the HP unit will follow the
signal of ON/OFF by Night mode contact.
Parameters
Level
Parameter
Function description
Display & Input value
Remarks
Group Code
Default
min.
Max.
Unit
I
51
28
T erminal 28-29 : Night mode
0=disable (Remote controller only)
1=enable
0
0
1
-
Par5128 and Par5130
are synchronized in
same value
I
41
11
Max. frequency of Night mode
80
50
100
5%
Night mode contact
Contact OPEN = Night mode OFF
Contact CLOSE = Night mode ON
28
29
PCB(Terminal)
Night
mode
Low tariff/Night mode
button
87