8
1.
2. Specifications
Model
AEYC-0639U-CH AEYC-1039U-CH AEYC-1639U-CH
Type
Heating and Cooling Monobloc Type
DC Inverter (Reverse cycle)
Power
1N ~ 230V 50Hz
Heating (*)
Capacity
[kW]
6.0
10.0
16.0
Power Input
[kW]
1.46
2.30
3.90
Running Current (MAX.)
[A]
6.4(11.2)
10.2(17.5)
17.0(25.3)
COP
4.11
4.35
4.10
Cooling (*)
Capacity
[kW]
5.0
8.0
16.0
Power Input
[kW]
1.28
2.32
4.10
Running Current (MAX.)
[A]
5.6(6.6)
10.1(11.6)
17.8(23.0)
EER
3.91
3.45
3.90
MAX. Pressure
[MPa]
4.1
Refrigerant (R410A)
[kg]
1.05
1.72
2.99
Dimentions & Weight (NET)
Height
[mm]
675
882
1,418
Width
[mm]
825
850
1,000
Depth
[mm]
300
330
330
Weight
[kg]
52
74
119
Temperature Range
Outdoor Temperature
Heating
[°C]
–20 to 43
Cooling
[°C]
18 to 43
20 to 43
15 to 43
Inlet Water Temperature
[°C]
18 to 55
Water Pressure
[MPa]
0.1 to 0.3
• Specifications are subject to change without notice.
(*) Rating condition Heating : Outdoor temperature DB/WB 7°C/6°C, Leaving water temperature 35°C
Cooling : Outdoor temperature 35°C, Leaving water temperature 18°C
• Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A).
According to IEC 704-1 and ISO 3744.
• If the air to water heat pump is operated under higher temperature conditions than those listed, the built-in protection circuit
may operate to prevent internal circuit damage. Also, during Cooling modes, if the unit is used under conditions of lower
temperatures than those listed above, it may freeze, leading to water leakage and other damage.