115
When the Backup heater is selected as Supplementary mode (Par4600=3), two different parameters Par4613
(Outdoor air temperature to enable Backup heater) and Par4614 (Outdoor air temperature hysteresis to disable
Backup heater) has to be defined to manage the function correctly.
Parameters
Level
Parameter
Function description
Display & Input value
Remarks
Group Code
Default
min.
Max.
Unit
I
46
00
B ackup heater type of function
0=disable
1=Replacement mode
2=Emergency mode
3=Supplementary mode
0
0
3
-
Par4600 and Par4700
are synchronized
Par4600=1, 2, 3
→ Par=4700=0
Par4700=1, 2
→ Par4600=0
I
46
10
C onditions to be available Backup heaters
0=always enabled
1=depends on Outdoor air temperature
1
0
1
-
I
46
11
Outdoor air temperature to enable Backup heaters and
disable compressor
-5.0
-20.0
20.0
0.5°C
I
46
12
Outdoor air temperature hysteresis to disable Backup
heaters and enable compressor
5.0
0.5
10.0
0.5°C
I
46
13
Outdoor air temperature to enable Backup heaters
(Supplementary mode)
5.0
-20.0
20.0
0.5°C
I
46
14
Outdoor air temperature hysteresis to disable Backup
heaters (Supplementary mode)
5.0
0.5
10.0
0.5°C
8. Domestic Hot Water Production