39
Note2: After 24:00, when the operation continues into the next day, set it to OFF at 24:00 on that day and then set it
to ON at 0:00 in the next day.
The time bands for both Zone1 and Zone2 can be set using the Master Remote controller. The Slave
Remote controller cannot be used for this setting.
0
Comfort:20℃
Economy:18℃
ON
OFF
ON OFF
ON
OFF
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Heating/Cooling time band
1st
2nd
3rd
Certain parameter lists are not included here; only a general description is presented, as follows.
For details, refer to the Parameter list at the end of this manual.
Zone1= Group11
Monday=1100~1108, Tuesday=1110~1118, Wednesday=1120~1128, Thursday=1130~1138,
Friday=1140~1148, Saturday=1150~1158, Sunday=1160~1168, Weekday (5days)=1170~1178,
Weekend (2days)=1180~1188, Every day (7days)=1190~1198
Zone2= Group12
Monday=1200~1208, Tuesday=1210~1218, Wednesday=1220~1228, Thursday=1230~1238,
Friday=1240~1248, Saturday=1250~1258, Sunday=1260~1268, Weekday (5days)=1270~1278,
Weekend (2days)=1280~1288, Every day (7days)=1290~1298
Parameter
Level
Parameter
Function description
Display & Input value
Remarks
Group
Code
Default
min.
Max.
Unit
U
01
16
H eating/Cooling time bands setting Zone1
0=disable
1=active (Comfort or Economy)
0
0
1
-
U
01
17
H eating/Cooling time bands setting Zone2
0=disable
1=active (Comfort or Economy)
0
0
1
-
U
01
18
D HW time band setting
0=disable
1=enable
0
0
1
-
I
11
00
T ime band is ON/OFF on Monday
0=OFF
1=ON
0
0
1
-
I
11
01
Comfort room set temperature on Monday
20.0
12.0
40.0
0.5°C
I
11
02
Economy room set temperature on Monday
18.0
12.0
40.0
0.5°C
I
11
03
1st ON time on Monday
0:00
0:00
24:00
15min
I
11
04
1st OFF time on Monday
0:00
0:00
24:00
15min
I
11
05
2nd ON time on Monday
0:00
0:00
24:00
15min
I
11
06
2nd OFF time on Monday
0:00
0:00
24:00
15min
I
11
07
3rd ON time on Monday
0:00
0:00
24:00
15min
I
11
08
3rd OFF time on Monday
0:00
0:00
24:00
15min
I
11
10
T ime band is ON/OFF on Tuesday
0=OFF
1=ON
0
0
1
-
I
11
11
Comfort room set temperature on Tuesday
20.0
12.0
40.0
0.5°C
I
11
12
Economy room set temperature on Tuesday
18.0
12.0
40.0
0.5°C
I
11
13
1st ON time on Tuesday
0:00
0:00
24:00
15min
I
11
14
1st OFF time on Tuesday
0:00
0:00
24:00
15min
I
11
15
2nd ON time on Tuesday
0:00
0:00
24:00
15min
I
11
16
2nd OFF time on Tuesday
0:00
0:00
24:00
15min
I
11
17
3rd ON time on Tuesday
0:00
0:00
24:00
15min
I
11
18
3rd OFF time on Tuesday
0:00
0:00
24:00
15min
5. Operation and functions of the Remote controller
Содержание AEYC-0639U-CH
Страница 156: ...20810030 M ...