154
11. Service and Maintenance
Monitor display
PCB
(Terminal)
Remote
controller
Function description
Display & Input value
Remarks
Number
Parameter
Default
min.
Max.
Unit
d0
01
00
Circulating water return temperature
-
-20
100
1°C
d1
01
01
Compressor operating frequency
-
0
200
1Hz
d2
01
02
Discharge temperature
-
-20
150
1°C
d3
01
03
Current consumption value
-
0
9900
100W
d4
01
04
Fan control number of rotation
-
0
1000
10rpm
d5
01
05
Defrost temperature
-
-20
100
1°C
d6
01
06
Outdoor air temperature
-
-20
100
1°C
d7
01
07
Water pump control number of rotation
-
0
9900
100rpm
d8
01
08
Suction temperature
-
-20
100
1°C
d9
01
09
Circulating water outgoing temperature
-
-20
100
1°C
01
10
Selected operating mode
0=Heating/Cooling OFF
1=Heating
2=Cooling
0
0
2
-
Set by
Remote controller
or remote contact
01
11
Room set temperature of Zone1(Master)
25.0
12.0
40.0
0.5°C
Set by Master Remote
controller
01
12
Room set temperature of Zone2(Slave)
25.0
12.0
40.0
0.5°C
Set by Slave Remote
controller
01
13
Selected DHW operating mode
0=disable
1=Comfort
2=Economy
3=Force
0
1
3
-
Set by
Remote controller
01
14
D ay
0=Monday, 1=Tuesday, 2=Wednesday,
3=Thursday, 4=Friday,5=Saturday,
6=Sunday
0
0
6
-
01
15
Clock
12:00
0:00
23:59
1min
01
16
Heating/Cooling time bands setting Zone1
0=disable
1=active
0
0
1
-
01
17
Heating/Cooling time bands setting Zone2
0=disable
1=active
0
0
1
-
01
18
DHW time band setting
0=disable
1=enable
0
0
1
-
01
19
Low tariff and Night mode setting
0=disable
1=Low tariff
2=Night mode
3=Low tariff and Night mode
0
0
3
-
Set by
Remote controller
or remote contact
01
20
Room relative humidity value
-
0
100
1%
Содержание AEYC-0639U-CH