Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive
44
(Need to connect IO
expansion card)
06: Zero-speed running(no output in stop)
07: Frequency upper limit arriving (
≥
F0-06
output)
08: Frequency lower limit arriving (
≤
F0-07
output)
09: PLC stage complete output
10: PLC cycle time complete output
11: Reserved
12: Torque level detection FDT output (F5-16
、
F5-17)
13: Motor overload pre-alarm
14: Run in forward( forward output)
15: Run in reverse( reverse output)
16: AC Drive overload pre-alarm
17: Set count value reached(F4-30)
18: Designated count value reached
(F4-31)
19: Length arrival indication(F4-27
~
F4-29)
20: At least one speed input
21: Input terminal S1 status
22: Input terminal S2 status
23: Input terminal S3 status
24: Input terminal S4 status
25: Input terminal S5 status
26: Input terminal S6 status
27: Digital output specified value(F5-34)
31: External fan start control(FA-21)
F5-04 Reserved
F5-05 Reserved
F5-06
SP1_HDO output
selection
0: Pulse output (HDO,F5-29
~
F5-32 setting)
1: Open collector output(SP1,F5-00 setting)
1
√
F5-07 SP1 closing delay time
0.0
~
3200.0s
0.0s
√
F5-08 SP1 cutting delay time
0.0
~
3200.0s
0.0s
√
F5-09
Relay T0 output closing
delay time
0.0
~
3200.0s
0.0s
√
F5-10
Relay T0 output cutting
delay time
0.0
~
3200.0s
0.0s
√
F5-11
Relay T1 output closing
delay time
0.0
~
3200.0s
0.0s
√
F5-12
Relay T1 output cutting
delay time
0.0
~
3200.0s
0.0s
√
F5-13
Frequency arrival (FAR)
detection width
0.0
~
100.0%(Maximum output frequency)
5.0%
√
*
F5-14
FDT Electric Level
detection value
00.00
~
F0-05
50.00Hz
√
*