Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive
36
2: Standby state (without output voltage)
F0-25
Minimum frequency of
deceleration to stop
0.00
~
5.00Hz( Free stop after deceleration to
this value)
0.00Hz
√
F0-26 Frequency
resolution
1: 0.1Hz
2: 0.01Hz
When modifying this function parameter, the
decimal places of all frequency-related
parameters will change.
2 ×
F0-27 Parameter
initialization
0: No operation
1: Initialize all parameters (include motor
parameters)
2: Clear fault record
0 ×
F0-28 Torque control enable
0: Speed control mode
1: Torque control mode(it is valid when F0-14
is set to 0)
0 ×
F0-29 Droop control rate
0.00
~
10.00Hz
This function is generally used for load
distribution when multiple motors are driving
the same load. The droop control means that as
the load increases, the output frequency of the
ac drive is reduced, and the load of multiple
motors is evenly realized. This parameter refers
to the output frequency drop value when the ac
drive outputs the rated load.
0.00Hz
√
F0-30
Main frequency
adjustment V1 low gain
0.0
~
F0-31(FA-13=1 is valid)
30.0%
√
F0-31
Main frequency
adjustment V1 high gain
F0-30
~
500.0%(FA-13=1 is valid)
320.0%
√
Group F1: Start/Stop Control Parameter Group
F1-00 Start function selection
Unit: start mode selection
0: Direct-on starting (F1-01
、
F1-02
、
F1-17)
1: DC braking first, then start(F1-03
、
F1-04)
2: Hardware speed tracking and restart (only
available for G7.5KW and bigger power,FA-15
~
FA-18)
3: Software tracking restart(F1-18
、
FA-18)
Ten digit: Terminal start protection selection
after normal power-on
0: Protection ( It needs to open the terminal and
then close the terminal to run in stop state)
1: No protection( Run when the terminal is
closed if there is no fault)
Hundred: Power-on terminal start protection
0000
√