Chapter 5 Functional Parameter Simple List 200 Series General Purpose Vector AC Drive
42
selection
09: Frequency setting increment (UP)
10: Frequency setting decreasing(DOWN)
11: Frequency increase/decrease (UP/DOWN)
setting clear
12: Multi-speed terminal 1
13: Multi-speed terminal 2
14: Multi-speed terminal 3
15: Multi-speed terminal 4
16: PID control pause
17: Swing frequency pause(stop at set
frequency)
18: Length count input
19: Acceleration and deceleration pause, except
for stop
20: Torque control forbidden(torque control,
forced to switch to speed control)
21: Length count reset
22: Simple PLC process reset
23: Acceleration and deceleration time 1
selection
24: Auxiliary frequency source selection
25: Reserved
26: Terminal count input
27: Terminal count reset
28: Deceleration DC braking (first decelerate to
DC braking frequency, then start DC braking,
after the terminal is released, continue normal
operation)
29: Lack water faulty signal input
30: S5 high speed pulse signal input
31: Running pause
F4-05
S6 terminal function
selection
0 ×
F4-09
Keyboard potentiometer
minimum input
0.00V
~
10.00V
0.50V
√
F4-10
Keyboard potentiometer
max input
0.00V
~
10.00V
9.50V
√
F4-11 V1 lower limit
0.00
~
F4-13
0.10V
√
F4-12
V1 lower limit
corresponds to the set
percentage
-100.0%
~
100.0%
0.0%
√
F4-13 V1 upper limit
F4-11
~
10.00V
9.90V
√
F4-14
V1 upper limit
corresponds to the set
percentage
-100.0
~
100.0%
100.0%
√