![CG Emotron VFX Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/cg/emotron-vfx-series/emotron-vfx-series_instruction-manual_2585388081.webp)
CG Drives & Automation, 01-5326-01r5
Operation via the Control Panel
77
Menu [100] Preferred view
This menu is displayed at every power-up. During
operation, the menu [100] will automatically be displayed
when the keyboard is not operated for 5 minutes.
Menu “[100] Preferred View” displays the settings made in
menu “[110], 1st line”, “[120], 2nd line” and
“[130], 3rd line”.
Extended signal monitoring
If you hold the
key when in menu [100] following
window will appear, as long as the key is pressed.
Here First, Second and Third line are shown as selected in
menu [100].
Then additional information will be displayed, selected in
the menus [140], [150] and [160] according to below.
Use menu “[170] View mode” to select active type of
menu [100] presentation, select if “Normal 100” or
“Always 100+” Extended signal monitoring” shall be
shown at power-up. A third choice is menu
“Normal100wo” = menu [100] without explaining text
at second and third line.
10.2.2 Editing mode
All other menus (read and read/write menus) are used in
following way.
During editing, preferred view will not be displayed and the
cursor will appear blinking to the left. See also below.
100
1240rpm
Torque
0% 0.0Nm
Current
123.3A
Sby
Key/Key
First line - set in Menu[110].
Second line - set in Menu[120]
Third line - set in Menu[130]
100
0rpm
3.9V
0.0A
0.0°C
0.0Hz
Sby
/Rem/Rem/--
First line - set in Menu[110].
Second line - set in Menu[120].
Third line - set in Menu[130].
Fourth line - set in Menu[140]
Sixth line - set in Menu[160]
Fifth line - set in Menu[150].
221
1240rpm
Motor Volts
M1
380V
Run
Key/Key
Shows Menu number to the left and to the right signal selected
Shows menu name to the left
Shows menu value to the right and if it is a Motor parameter active
Shows Drive status/Parameter set and Control source as in menu [100]
in menu [110].
Motor set (M1 in this case) is displayed to the left.
211
Language
English
Run
Loc/Loc
Preferred view is not shown during editing.
= blinking during editing
Содержание Emotron VFX Series
Страница 1: ...Emotron VFX 2 0 AC drive Instruction manual English Valid from software version 4 42...
Страница 2: ......
Страница 4: ......
Страница 10: ...6 CG Drives Automation 01 5326 01r5...
Страница 50: ...46 Installation CG Drives Automation 01 5326 01r5...
Страница 62: ...58 Getting Started CG Drives Automation 01 5326 03r5...
Страница 74: ...70 EMC and standards CG Drives Automation 01 5326 01r5...
Страница 90: ...86 Operation via the Control Panel CG Drives Automation 01 5326 01r5...
Страница 218: ...216 CG Drives Automation 01 5326 01r5...
Страница 226: ...224 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r5...
Страница 236: ...234 Options CG Drives Automation 01 5326 01r5...
Страница 256: ...254 Technical Data CG Drives Automation 01 5326 01r5...
Страница 267: ......