![CG Emotron VFX Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/cg/emotron-vfx-series/emotron-vfx-series_instruction-manual_2585388005.webp)
CG Drives & Automation, 01-53
26
-01r5
1
Safety Instructions
Congratulations for choosing a product from CG Drives &
Automation!
Before you begin with installation, commissioning or
powering up the unit for the first time it is very important
that you carefully study this Instruction manual.
Following symbols can appear in this instruction or on the
product itself. Always read these first before continuing.
Handling the AC drive
Installation, commissioning, demounting, taking
measurements, etc, of or on the AC drive may only be
carried out by personnel technically qualified for the task.
A number of national, regional and local regulations govern
handling, storage and installation of the equipment. Always
observe current rules and legislation.
Opening the AC drive
Always take adequate precautions before opening the AC
drive. Although the connections for the control signals and
the switches are isolated from the main voltage, do not
touch the control board when the AC drive is switched on.
Incorrect connection
The AC drive is not protected against incorrect connection
of the mains voltage, and in particular against connection of
the mains voltage to the motor outlets U, V and W. The AC
drive can be damaged in this way. Risk for personal injury.
Precautions to be taken with a
connected motor
If work must be carried out on a connected motor or on the
driven machine, the mains voltage must always be
disconnected from the AC drive first. Wait at least 7minutes
before starting work.
Earthing
The AC drive must always be earthed via the mains safety
earth connection.
Earth leakage current
Residual current device (RCD)
compatibility
This product cause a DC current in the protective
conductor.
Where a residual current device (RCD) is used
for protection in case of direct or indirect contact, only a
Type B RCD is allowed on the supply side of this product.
Use RCD of 300 mA minimum.
EMC Regulations
In order to comply with the EMC Directive, it is absolutely
necessary to follow the installation instructions. All
installation descriptions in this manual follow the EMC
Directive.
NOTE: Additional information as an aid to avoid
problems.
CAUTION!
Failure to follow these instructions can
result in malfunction or damage to the
AC drive.
Warning!
Failure to follow these instructions can
result in serious injury to the user in
addition to serious damage to the AC
drive.
HOT SURFACE!
Failure to follow these instructions can
result in injury to the user.
WARNING!
Always switch off the mains voltage
before opening the AC drive and wait
at least 7 minutes to allow the
capacitors to discharge.
!
CAUTION!
This AC drive has an earth leakage
current which does exceed 3.5 mA AC.
Therefore the minimum size of the
protective earth conductor must comply with the
local safety regulations for high leakage current
equipment which means that according to the
standard IEC61800-5-1 the protective earth
connection must be assured by one of following
conditions:
PE conductor cross-sectional area shall for
phase cable size < 16 mm
2
(6 AWG) be >10 mm
2
Cu (16 mm
2
Al) or use a second PE conductor
with same area as original PE conductor.
For cable size above 16 mm
2
(6 AWG) but smaller
or equal to 35mm
2
(2 AWG) the PE conductor
cross-sectional area shall be at least 16mm
2
(6 AWG).
For cables >35 mm
2
(2 AWG) the PE conductor
cross-sectional area should be at least 50 % of
the used phase conductor.
When the PE conductor in the used cable type is
not in accordance with the above mentioned
cross-sectional area requirements, a separate
PE conductor should be used to establish this.
!
Содержание Emotron VFX Series
Страница 1: ...Emotron VFX 2 0 AC drive Instruction manual English Valid from software version 4 42...
Страница 2: ......
Страница 4: ......
Страница 10: ...6 CG Drives Automation 01 5326 01r5...
Страница 50: ...46 Installation CG Drives Automation 01 5326 01r5...
Страница 62: ...58 Getting Started CG Drives Automation 01 5326 03r5...
Страница 74: ...70 EMC and standards CG Drives Automation 01 5326 01r5...
Страница 90: ...86 Operation via the Control Panel CG Drives Automation 01 5326 01r5...
Страница 218: ...216 CG Drives Automation 01 5326 01r5...
Страница 226: ...224 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r5...
Страница 236: ...234 Options CG Drives Automation 01 5326 01r5...
Страница 256: ...254 Technical Data CG Drives Automation 01 5326 01r5...
Страница 267: ......