161
Max Alarm delay [4162]
When the load level without interruption exceeds the alarm
level longer than set “Max Alarm delay” time, an alarm is
activated.
Communication information
Max Pre Alarm [417]
Max Pre AlarmMargin [4171]
With load type Basic [415], used the Max Pre-Alarm Margin
sets the band above the Normal Load, [41B], menu that
does not generate a pre-alarm. With load type Load Curve,
[415], used the Max Pre-Alarm Margin sets the band above
the Load Curve, [41C], that does not generate a pre-alarm.
The Max Pre-Alarm Margin is a percentage of nominal
motor torque.
In case of Load Curve R, the margin is percentage of Load
curve torque at the actual speed.
Communication information
Max Pre Alarm delay [4172]
When the load level without interruption exceeds the alarm
level longer than set “Max PreAlarm delay” time, a warning
is activated.
Communication information
Min Pre Alarm [418]
Min Pre Alarm Margin [4181]
With load type Basic, [415], used the Min Pre-Alarm
Margin sets the band under the Normal Load, [41B], menu
that does not generate a pre-alarm. With load type Load
Curve, [415], used the Min Pre-Alarm Margin sets the band
under the Load Curve, [41C], that does not generate a
pre-alarm. The Min Pre-Alarm Margin is a percentage of
nominal motor torque.
In case of Load Curve R, the margin is percentage of Load
curve torque at the actual speed.
Communication information
4162
MaxAlarmDel
Default:
0.1 s
Range:
0-90 s
Modbus Instance no/DeviceNet no:
43330
Profibus slot/index
169/234
EtherCAT and CANopen index (hex)
4d02
Profinet IO index
19714
Fieldbus format
Long, 1=0.1 s
Modbus format
EInt
4171
MaxPreAlMar
Default:
10%
Range:
0–400%
Modbus Instance no/DeviceNet no:
43327
Profibus slot/index
169/231
EtherCAT and CANopen index (hex)
4cff
Profinet IO index
19711
Fieldbus format
Long, 1=1%
Modbus format
EInt
4172
MaxPreAlDel
Default:
0.1 s
Range:
0–90 s
Modbus Instance no/DeviceNet no:
43331
Profibus slot/index
169/235
EtherCAT and CANopen index (hex)
4d03
Profinet IO index
19715
Fieldbus format
Long, 1=0.1 s
Modbus format
EInt
4181
MinPreAlMar
Default:
10%
Range:
0-400%
Modbus Instance no/DeviceNet no:
43328
Profibus slot/index
169/232
EtherCAT and CANopen index (hex)
4d00
Profinet IO index
19712
Fieldbus format
Long, 1=1%
Modbus format
EInt
Содержание Emotron VFX Series
Страница 1: ...Emotron VFX 2 0 AC drive Instruction manual English Valid from software version 4 42...
Страница 2: ......
Страница 4: ......
Страница 10: ...6 CG Drives Automation 01 5326 01r5...
Страница 50: ...46 Installation CG Drives Automation 01 5326 01r5...
Страница 62: ...58 Getting Started CG Drives Automation 01 5326 03r5...
Страница 74: ...70 EMC and standards CG Drives Automation 01 5326 01r5...
Страница 90: ...86 Operation via the Control Panel CG Drives Automation 01 5326 01r5...
Страница 218: ...216 CG Drives Automation 01 5326 01r5...
Страница 226: ...224 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5326 01r5...
Страница 236: ...234 Options CG Drives Automation 01 5326 01r5...
Страница 256: ...254 Technical Data CG Drives Automation 01 5326 01r5...
Страница 267: ......