TROUBLE SHOOTING
KEY ELEMENTS FOR TROUBLE FREE OPERATION
Make
certain:
Unit is plugged into a proper electrical outlet.
Unit is turned on.
Wire Straightener is adjusted properly.
Roller Pressure is adjusted properly.
Correct Input Guide Tube and Exit Guide are being used.
Data entered is correct and accurate.
Prefeed is being used if required.
COMMON PROBLEMS SOLUTIONS
Display reads:
1. Check for proper Wire Guide.
ERROR-CHECK GUIDE TUBE
2. Check adjustment on Wire Straightener.
3. Check Feed Speed.
4. Check Roller Pressure.
Display reads:
1. Increase Trailing Feed Roller Pressure.
INCREASE TRAILING
2. Check for proper Wire Guide.
FEED ROLLER PRESSURE
3. Check adjustment on Wire Straightener.
4. Check Feed Speed.
Display reads:
1. Check Blade Speed and select slower speed.
*** BLADE ERROR ***
2. Check gauge of material being processed.
PLEASE PRESS ENTER
Length Inaccuracies
1. Check Feed Speed.
2. Check Roller Pressure.
3. Verify Length setting.
4. Check adjustment on Wire Straightener. Wire must have
proper/consistent pressure through straightener.
5. Check adjustment on Centering Roller Guides.
6. Motorized Prefeed may be required.
Wire Jams
1. Check for proper Input Guide Tube.
2. Check for proper Exit Guide.
3. Check for slugs in Exit Guide.
4. Air Blast option may be necessary. Check for proper PSI.
5. Check Roller Pressure. Setting may be too high.
6. Check Feed Speed.
#3876 Screws - 4pcs.
#6134 Clamp Collar