PROGRAMMING
SHORT MODE
cont.
LENGTH CORRECTION
The Model 93 has a Length Correct feature that allows the operator to make adjustments from the preprogrammed length
versus the actual sample length. This feature allows for correction for both overall cut length and strip length. Small
variations from the programmed value to the actual value are normal due to differences in material, tension, friction, wire
diameter etc. If the sample wire did not have the correct length and/or strip length select the
LENGTH CORRECT
key for
adjustments.
LCD DISPLAY PROMPT
ACTION REQUIRED
PLEASE ENTER
This screen is used to make corrections to the
overall
length. Measure the length of
MEASURED WIRE LENGTH
your sample piece. If overall length correction is necessary enter the actual measured
value and then Press
ENTER.
The Model 93 will automatically calculate the correction
necessary. Run several test pieces to check correction. NOTE: If the overall length
requires no correction do not enter a value.
PLEASE ENTER
This screen is used to make corrections to the
strip
length. If strip length corrections
SHORT
MODE
are necessary proceed as follows: First, run several test pieces to insure overall length
CORRECTION VALUE
is correct. Then, measure the Leading End of your sample pieces. The CORRECTION
CORRECT= 0.00
VALUE will be the difference between the programmed dimension and the actual
measured dimension. Enter this value and then Press
ENTER
. Run several test pieces
to check correction. NOTE:If the strip length requires no correction do not enter a
value.
The possible range of correction is +/- 10% of the overall wire length. If a value outside of this range is entered an error
message will appear and display the acceptable range of values.
The length correct value may be changed multiple times but typically a single entry is all that is required if the sample wire
was measured accurately and the data entered correctly.
RUN PROGRAM
After you have produced a satisfactory sample wire and all settings are correct press
RUN.
This will process your current
program. The same warning will appear as noted above in SINGLE CYCLE. Make sure that the Exit Guide and Trailing
Strip Rollers are removed.
STOP PROGRAM
If at any time you need to stop your processing press
STOP.
This action will stop the processing and wire feed.