CARPENTER MODEL 93 COMPU-STRIP
Phone: 315-682-9176 Fax: 315-682-9160
Page
40
Revised 08/23/13 Website: www.carpentermfg.com E-mail: [email protected]
DISTANCE _.__
each marking along the wire. Minimum distance is 0.50” or 0.00”(off). Enter “0” to
bypass this option. Press
ENTER.
Press either key to activate Marker Setup Cycle. At this point the Model 93 and the
attached marker will go into a setup cycle. The two units are now automatically
synchronized to apply the marks in the locations along the wire as previously
programmed.
Process a few sample pieces. Measure the location of the center of the leading end mark from the leading end of wire. If
the measured dimension is not equal to the programmed Leading End Mark dimension, proceed with the following:
CARPENTER MODEL 93 COMPU-STRIP
OPTIONAL FEATURES
cont.
WIRE MARKER
cont.
LEADING END MARK DISTANCE CORRECTION
Press
MENU
key until you reach WIRE MARKER. Press
ENTER.
Scroll through WIRE MARKER by pressing
ENTER
key until the statement below is displayed.
The following prompt will only display after a sample piece has been run using the
SINGLE CYCLE
or
RUN
key.
LCD DISPLAY PROMPT
ACTION REQUIRED
PLEASE ENTER
Enter the measured Leading End Mark distance of sample wire.
MEASURED LEADING END
Press
ENTER.
MARK
DISTANCE
_.__
Press either key to activate Marker Setup Cycle. The Model 93 and the attached
marker
will again go into a setup cycle and at this point the marks will have been shifted to
their
correct locations and normal processing can begin.
NOTES:
A marker correction value can only be entered once. After the value has been entered, the software will only display
the previously entered value, it will not allow it to be changed. The correction feature is very accurate. Assuming the
mark position was measured correctly and the correct measured value was entered, the software will correct it
adequately with only one entry.
If it becomes necessary to re-enter the correction data, you will first have to re-enter the Leading End Mark Distance.
This will cancel out the original correction value and allow entry of a new value after the marker has cycled through the
setup cycle.
If, after setting up the marker and running a few pieces, it becomes necessary to use both the Leading End Mark
correction and Length Correct features, the Leading End Mark correction must be done first and the
RUN
or
SINGLE
CYCLE
key pressed to setup the system with the new values. After this has been done, the Length Correct value can
be entered. It is imperative that the information be entered in this sequence. If the Length Correct value is entered
before the Leading End Mark correction, the Length Correct value will be reset to the Wire Length value when the
Leading End Mark correction information is entered.
RUN
SINGLE
CYCLE
RUN
SINGLE
CYCLE