CDE360 Vector Control AC Drive Chapter 6 Parameters Description
-
90
-
A0.26
Range: 0~65535
Default: 0
Actual length
Unit: m
It display value of
A0.25
divide to
E7.08
, it is used for fixed length control.
A0.27
Range: 0.0~6553.5
Default: 0.0
Linear speed
Unit: m/Min
It displays value of sample number at every minute divide to
E7.08
.
A0.28
Range: 0.0~6553.5
Default: 0.0
Remaining
running time
Unit: Min
It displays the remaining running time when the timing operation is
enabled. For details on timing operation, refer to
Eb.00
to
Eb.02
.
A0.29
Range: 0.00~
b0.00
Default: 0.00
Swing center
frequency
Unit: Hz
For details on timing operation, refer to parameters in group E7.
A0.30
Range: 0~65535
Default: 0
Load speed
It display the output frequency multiply by H0.08, the min unit is decided
by H0.09.
For example, in place of machine tool, the drive is not trail the equipment
indirectly, it connect with a variable machine at first. Set the value of H0.08
suitably, customs could use keypad to watch the actual rotational speed of
the machine.
A0.31
Range: -
b0.00
~
b0.00
Default: 0.00
Feedback speed
Unit: Hz
It displays the actual output frequency of the drive.
A0.32
Range: 0000~4444
Default: 0000
Multi-pump
status word
It displays the status of each in Multi-pump control mode.
0:in interlock or not used
3: connect to power grid
1: ready
4: connect to AC drive
2: wait for change
Unit's digit: 1# pump status
Ten's digit: 2# pump status
Hundred's digit: 3# pump status
Thousand's digit: 4# pump status
A0.33
Range: -320.00~320.00
Default: 0.00
Encoder
detection speed
Unit: Hz
It displays the motor running frequency measured by the encoder.