CDE360 Vector Control AC Drive Chapter 2 Product Information
2.8 Recommendation of Brake Resistance Selection
Table 2- 6 Brake resistance selection table of CDE360 series
AC drive voltage
&power classes
Recommended
power
(
kW
)
Recommended
resistance
(
Ω
)
Brake Unit
Single phase 220V input
2S0R7
0.15
100
Built-in
2S1R5
0.2
75
Three phase 380V input
4T0R7G/1R5L
0.45
≥ 150
Built-in (Standard)
4T1R5G/2R2L
0.45
≥ 150
4T2R2G/3R7L
0.6
≥ 120
4T3R7G/5R5L
0.7
≥ 100
4T5R5G/7R5L
0.8
≥ 80
4T7R5G/011L
1
≥ 65
4T011G/015L
1.5
≥ 43
4T015G/018L
2.0
≥ 32
4T018G/022L
2.5
≥ 30
4T022G/030L
3
≥ 24
4T030G/037L
3.7
≥ 16
4T037G/045L
5
≥ 14
External (Optional) 60A
4T045G/055L
4T055G/075L
7
≥ 10
External (Optional) 80A
4T075G/090L
8.5
≥ 8
External (Optional) 150A
4T090G/110L
14
≥ 5
4T110G/132L
Three phase 480V input
5T0R7G/1R5L
0.45
≥ 200
Built-in (Standard)
5T1R5G/2R2L
0.45
≥ 200
5T2R2G/3R7L
0.6
≥ 150
5T3R7G/5R5L
0.7
≥ 120
5T5R5G/7R5L
0.8
≥ 100
5T7R5G/011L
1
≥ 75
5T011G/015L
1.5
≥ 51
5T015G/018L
2.0
≥ 39
5T018G/022L
2.5
≥ 36
5T022G/030L
3
≥ 29
5T030G/037L
3.7
≥ 20
5T037G/045L
5
≥ 18
External (Optional) 60A
5T045G/055L
5T055G/075L
7
≥ 12
External (Optional) 80A
5T075G/090L
8.5
≥ 10
External (Optional) 150A
5T090G/110L
14
≥ 6
External (Optional) 150A