CDE360 Vector Control AC Drive Chapter 2 Product Information
Item
Specifications
Protection
function
Common types
Input and output phase loss protection,under voltage protection,
over voltage protection,over current protection,over heat protection,
over load protection,short-circuit protection, module fault, external
fault, self-defining fault.
Environment
Installation location
Indoor, free from direct sunlight, dust,drip, salt, oil smoke, water
vapor, combustible gas and corrosive gas.
Altitude
If the altitude is equal or lower than 1000 meters, the AC drive can
be used normally.
If the altitude is higher than 1000 meters, it is necessary to de-rate
the AC drive. The ratio of derating the AC drive is 1 percent for
every increase of 100 meters.
If the altitude is higher than 3000 meters, please contact our
agents.
Temperature
-10
℃
to +40
℃
.
If the ambient temperature is 40
℃
to 50
℃
, please keep good
ventilation and take the action of derating: The ratio of derating the
AC drive is 3 percent for every increase of 1
℃
.
Humidity
Less than 95%RH, without condensing.
Vibration
Less than 0.6g
Storage temperature
-
25
℃
~+
65
℃