Section 8. Processing and Program Control Examples
8-3
*
1
Table 1 Programs
01:
5
Sec. Execution Interval
01:
P2
Volt (DIFF)
01:
1
Rep
02:
35
2500mV 50Hz rejection
03:
3
IN Chan
04:
5
Loc [:XX mg/M3 ]
05:
10
Mult
06:
0
Offset
02:
P92
If time is
01:
0
minutes into a
02:
60
minute interval
03:
10
Set high Flag 0 (output)
03:
P80
Set Active Storage Area
01:
3
Input Storage Area
02:
3
Array ID or location
04:
P71
Average
01:
1
Rep
02:
5
Loc XX mg/M3
05:
P51
Spatial Average
01:
3
Swath
02:
1
First Loc AVG i-2
03:
4
Avg Loc [:3 HR AVG ]
06:
P80
Set Active Storage Area
01:
1
Final Storage Area 1
02:
25
Array ID or location
07:
P77
Real Time
01:
110
Day, Hour-Minute
08:
P70
Sample
01:
1
Reps
02:
4
Loc 3 HR AVG
09:
P91
If Flag/Port
01:
10
Do if flag 0 (output) is high
02:
30
Then Do
10:
P54
Block Move
01:
2
No. of Values
02:
2
First Source Loc AVG i-1
03:
1
Source Step
04:
1
First Dest. Loc [:AVG i-2 ]
05:
1
Destination Step
11:
P95
End
12:
P
End Table 1