CR10X User Guide
8-6
Example Program Multiplexing Thermocouples and Soil Moisture Blocks
Input Location Labels:
1 Ref_Temp
12 TC_#11
23 Soil_#6
2 TC_#1
13 TC_#12
24 Soil_#7
3 TC_#2
14 TC_#13
25 Soil_#8
4 TC_#3
15 TC_#14
26 Soil_#9
5 TC_#4
16 TC_#15
27 Soil_#10
6 TC_#5
17 TC_#16
28 Soil_#11
7 TC_#6
18 Soil_#1
29 Soil_#12
8 TC_#7
19 Soil_#2
30 Soil_#13
9 TC_#8
20 Soil_#3
31 Soil_#14
10 TC_#9
21 Soil_#4
32 Soil_#15
11 TC_#10
22 Soil_#5
33 Soil_#16
*
1
Table 1 Programs
01:
600
Sec. Execution Interval
01:
P11
Temp 107 Probe
01:
1
Rep
02:
4
IN Chan
03:
1
Excite all reps w/EXchan 1
04:
1
Loc [:REF TEMP ]
05:
1
Mult
06:
0
Offset
02:
P86
Do
01:
41
Set high Port 1
03:
P87
Beginning of Loop
01:
0
Delay
02:
16
Loop Count
04:
P86
Do
01:
72
Pulse Port 2
05:
P22
Excitation with Delay
01: 1
Ex Channel
02: 0
Delay W/Ex (units=0.01sec)
03: 1
Delay after Ex (units=0.01sec)
04: 0
mV Excitation
06:
P14
Thermocouple Temp (DIFF)
01:
1
Rep
02:
31
2.5mV 50Hz rejection Range
03:
1
IN Chan
04:
1
Type T (Copper-Constantan)
05:
1
Ref Temp Loc REF TEMP
06:
2--
Loc [:TC TEMP#1]
07:
1
Mult
08:
0
Offset