SDM-CD16/16ACs may be addressed, making it possible to control a maximum
of 256 ports from the first three datalogger control ports.
For each repetition, the states of the 16 ports of the addressed SDM-CD16/16AC
are sent according to 16 sequential input locations starting at the input location
specified in parameter 3. Any non-zero value stored in an input location activates
(connects to ground) the associated SDM-CD16/16AC port. A value of zero (0)
deactivates the port (open circuit). For example, assuming two repetitions and a
starting input location of 33, outputs 1 to 16 of the first SDM-CD16/16AC are set
according to input locations 33 to 48, and outputs 1 to 16 of the second
SDM-CD16/16AC are set according to input locations 49 to 64. See the
SDM-CD16/16AC manuals for detailed instructions and examples.
PARAM.
DATA
NUMBER
TYPE
DESCRIPTION
1
2
Reps (no. of CD16/16AC modules sequentially
addressed)
2
2
Starting Address (base 4: 00..33)
3
4
Starting input location
Input locations read:
16 per repetition
Instruction 105: SDI-12 Recorder
Instruction 105 allows data to be collected from an SDI-12 sensor. A single
control port is connected to the SDI-12 sensor data line and the SDI-12 ground is
connected to a ‘G’ terminal on the CR10X wiring panel. The CR10X may also be
used as the 12V power supply for sensors. If multiple SDI-12 sensors are used, up
to ten sensors may be connected to a single control port, but each sensor must
have a unique address and requires a separate Instruction 105.
Version 1.2 of the SDI-12 specification has been implemented in
the CR10X. Features added in this version are marked with the
dagger symbol(
✝
) and may not be supported by older SDI-12
sensors.
PARAM.
DATA
NUMBER
TYPE
DESCRIPTION
01:
4
Address (0-9,
✝
10-126)
02:
2
Command (Table 9-8)
03:
2
Port (C1-C8)
04:
4
Input location
05:
FP
Multiplier
06:
FP
Offset
Input locations altered: 0-9 (
✝
1-99) depending on the SDI-12 sensor
Intermediate Locations required: 21
NOTE