CR10X Reference Manual
11-12
09:
2
Option (AB)
A: Form 0 = closed, 1 = open form
B: Output 0 = fraction, 1 = counts
10:
4
Input location to start storing histogram. Enter 0 to
send output directly to Final Storage.
Execution time: 6.5 - 7.0ms, with 60 Amplitude Bins and one Mean Bin.
Intermediate Storage locations required: Reps x (Bins+2 x [No. of Amplitude
Bins] + 4), where Bins = No. Mean Bins x No. Amplitude Bins.
Outputs generated: No. Mean Bins x No. Amplitude Bins x Reps
Instruction 82: Standard Deviation in Time
This instruction calculates the standard deviation (STD DEV) of a given input
location. The standard deviation is calculated using the formula:
S = ((
Σ
X
i
2
- (
Σ
X
i
)
2
/N)/N)
1/2
where X
i
is the ith measurement and N is the number of samples.
PARAM.
DATA
NUMBER TYPE
DESCRIPTION
01:
2
Repetitions
02:
4
Starting input location no.
Outputs Generated:
1 per repetition