Chapter 21: Alarms List
PoE Injector Pin-outs and LEDs – Passive PoE
phn-3963_008v000
Page 21-17
Alarm ID
Type
Description
Severity
Probable Cause
Corrective Action
Notes
1007
Alarm
Radio protection no mate
Major
Radio protection function is missing
radio module, module defected or
disabled
1.
Add radio module.
14.
Replace a defective existing
radio module.
15.
Make sure all radio interfaces
are enabled.
1008
Event
Remote switchover request
was sent - reason
Warning
1009
Alarm
Rdadio protection lockout
command is on.
Major
The user has issued a lockout
command
Clear the lockout command
1010
Event
Ethernet interface Group
protection switchover
Warning
1.
LOC event on an Ethernet
interface.
16.
Protection group member was
disabled or pulled out of the
shelf.
1.
Check the system for local
failures.
17.
Check external equipment.
1011
Alarm
Interface protection lockout is
on
Major
1.
The user has issued a lockout
command
1.
Clear the lockout command
1012
Alarm
Interface protection no mate:
mate interface is missing or
disabled
Major
Interface protection function is
missing interface module, module
defected or diabled
1.
Add interface module.
18.
Replace a defective existing
interface module.
19.
Make sure all interface
interfaces are enabled.
1102
Event
Software installation status:
Warning
1105
Event
New version installed
Warning
A software version has been
installed but system has not been
reset.
Содержание PTP 850E
Страница 1: ...User Guide PTP 850E System Release 10 9 ...
Страница 48: ...Chapter 2 Getting Started PC Setup phn 3963_008v000 Page 2 5 Figure 10 Internet Protocol Properties Window ...
Страница 502: ...Chapter 19 Alarm Management and Troubleshooting CLI Performing Diagnostics CLI phn 3963_008v000 Page 19 29 ...