Chapter 21: Alarms List
PoE Injector Pin-outs and LEDs – Passive PoE
phn-3963_008v000
Page 21-44
Alarm ID
Type
Description
Severity
Probable Cause
Corrective Action
Notes
5014
Alarm
The pipe interface clock-source
in signal-interface table is not
system-clock
Major
5015
Alarm
The pipe is missing an edge
interface
Major
5016
Alarm
Pipe interface operational state
is down
Major
5017
Alarm
Pipe is invalid
Major
5018
Alarm
1588TC is not operational
Major
System Failure
Reboot the unit
5030
soam-
connectivi
ty-failure
A connectivity failure in
MA/MEG
Minor
Specific defect dependent: User
configuration , connectivity loss.
Reconfigure the RPL.
5031
soam-def-
error-
failure
Error CCM received
Major
Invalid CCMs has been received
Check the link in the traffic path
(1)
5032
soam-def-
mac-
failure
Remote mep MAC status not
up
Minor
Remote MEP’s associated MAC is
reporting an error status
Check remote MEP's MAC status
(1)
5033
soam-def-
rdi-failure
Mep Rdi received
Minor
Remote Defect indication has been
received from remote MEP
Check the SOAM configurations
(1)
5034
soam-
remote-
ccm-
failure
Remote mep CCMs are not
received
Major
The MEP is not receiving CCMs
from at least one of the remote
MEPs
Check that all remote MEPs are
configured or enbaled
(1)
Содержание PTP 850E
Страница 1: ...User Guide PTP 850E System Release 10 9 ...
Страница 48: ...Chapter 2 Getting Started PC Setup phn 3963_008v000 Page 2 5 Figure 10 Internet Protocol Properties Window ...
Страница 502: ...Chapter 19 Alarm Management and Troubleshooting CLI Performing Diagnostics CLI phn 3963_008v000 Page 19 29 ...