Chapter 21: Alarms List
PoE Injector Pin-outs and LEDs – Passive PoE
phn-3963_008v000
Page 21-49
Alarm ID
Type
Description
Severity
Probable Cause
Corrective Action
Notes
5102
Alarm
Payload REncryption failure
Critical
1.
Radio LOF on Tx/Rx direction.
2.
The session key does not
match across the link.
3.
The AES admin setting does
not match across the link.
1.
Validate the MSE on both
sides of the link.
2.
Validate the session key on
both sides of the link.
3.
Validate the AES admin
setting on both sides of the
link.
(1)
5103
Event
Key Exchange Protocol
successfully finished
Indeterminate
(1)
5104
Event
Key Exchange Protocol initiated Indeterminate
(1)
5105
Event
Key Exchange Protocol initiated
by remote side
Indeterminate
(1)
5106
Event
Key Zeroization command
executed
Indeterminate
(1)
5107
Alarm
FIPS Bypass Self-Test failed
Critical
Disk failure
(1)
5108
Alarm
Power On Self-Test Failed
Critical
System failure
Reboot the unit.
(1)
5033
Alarm
Communications
Critical
Radio script is incompatible to
AMCC
Set AFR Script in both Agg1 & Agg2
carriers
(1)
5034
Alarm
Communications
Critical
Inconsistent MRMC script between
members
Set the members to the
appropriate MRMC script
(1)
5035
Alarm
Communications
Critical
Inconsistent radio frequency
Set same radio TX/RX frequency on
all AMCC carriers
(1)
5100
Alarm
Communications
Critical
Agg 1 failed Bring-up procedure
Drop both Agg1 & Agg2 into single
carrier mode (Pre-Init)
(1)
5101
Alarm
Communications
Critical
Invalid ACM configuration
Set AMCC member to adaptive
ACM profiles
(1)
Содержание PTP 850E
Страница 1: ...User Guide PTP 850E System Release 10 9 ...
Страница 48: ...Chapter 2 Getting Started PC Setup phn 3963_008v000 Page 2 5 Figure 10 Internet Protocol Properties Window ...
Страница 502: ...Chapter 19 Alarm Management and Troubleshooting CLI Performing Diagnostics CLI phn 3963_008v000 Page 19 29 ...