Chapter 21: Alarms List
PoE Injector Pin-outs and LEDs – Passive PoE
phn-3963_008v000
Page 21-30
Alarm ID
Type
Description
Severity
Probable Cause
Corrective Action
Notes
1775
Alarm
RFU software download is not
possible.
Critical
Wrong type of XCVR, the XCVR
hardware is METRO.
Replace the XCVR
1776
Alarm
RMC hardware failure.
Major
RMC hardware failure of the clock
distributor.
Replace the RMC.
1780
Event
MRMC running script is deleted Warning
New installed software package
does not include the running
MRMC radio script
Make sure the required software
package include the running MRMC
radio script.
Download and install the correct
software package.
1781
Event
MRMC running script is
updated
Warning
New installed software package
does has an updated version of the
running MRMC radio script
Reset the radio carrier to reacquire
the new updated MRMC radio
script
1782
Alarm
2.5Gbps mismatch
configuration
Warning
The card can not function outside
of an ABC group in 2.5Gbps mode.
Add the card to an ABC group, or
change the Slot Section to 1Gbps.
1783
Alarm
Radio remote fault indication
(RFI)
Minor
1790
Alarm
Hardware failure
Critical
An internal hardware failure has
been detected by the system.
Replace the card or unit reporting
the hardware failure.
1800
Alarm
T3 sync interface Loss of Carrier Major
1.
Cable disconnected.
Defective cable.
1.
Check connection of the cable.
Replace the cable.
2001
Alarm
TDM-LIC has rebooted and is
not in service now
Major
1.
Recent TDM-LIC card reset;
System malfunction.
1.
Wait for card to reboot.
Reset the TDM-LIC card.
2002
Alarm
TDM-LIC configuration
mismatch
Major
1.
Recent warm reset of TDM-
LIC;
System malfunction.
Power cycle the TDM-LIC.