Chapter 8: Synchronization
Configuring the Outgoing Clock and SSM Messages
phn-3963_008v000
Page 8-6
Configuring the Outgoing Clock and SSM Messages
In the Outgoing Clock page, you can view and configure the following synchronization settings per interface:
•
The interface's clock source (outgoing clock).
•
For radio interfaces, the synchronization radio channel (used for interoperability).
•
SSM message administration.
Note
SSM message administration is not supported in release 10.6. It is supported in release 10.9.
In order to provide topological resiliency for synchronization transfer, PTP 850E implements the passing of SSM
messages over the radio interfaces. SSM timing in PTP 850E complies with ITU-T G.781.
In addition, the SSM mechanism provides reference source resiliency, since a network may have more than one
source clock. The following are the principles of operation:
•
At all times, each source interface has a “quality status” which is determined as follows:
o
If quality is configured as fixed, then the quality status becomes “failure” upon interface failure (such as
LOS, LOC, LOF).
o
If quality is automatic, then the quality is determined by the received SSMs. If no valid SSM messages are
received or in case of interface failure (such as LOS, LOC, LOF), the quality becomes "failure.
•
Each unit holds a parameter which indicates the quality of its reference clock. This is the quality of the current
synchronization source interface.
•
The reference source quality is transmitted through SSM messages to all relevant radio interfaces.
•
In order to prevent loops, an SSM with quality “Do Not Use” is sent from the active source interface (both
radio and Ethernet)
In order for an interface to transmit SSM messages, SSM must be enabled on the interface. By default, SSM is
disabled on all interfaces.
When configuring the outgoing clock and SSM administration, the Sync mode must be set to its default setting of
automatic. To display the current Sync mode, enter the following CLI command in root view:
root> platform sync mode show
If the Sync mode is set to pipe, you must set it to automatic by entering the following CLI command in root view:
root> platform sync mode set automatic
To configure the outgoing clock on an Ethernet interface, the Media Type of the interface must be RJ45 or SFP, not
Auto-Type. To view and configure the Media Type of an Ethernet interface, see
Configuring Ethernet Interfaces
To view and configure the synchronization parameters of the unit’s interfaces:
1
Select
Sync > Outgoing Clock
. The Outgoing Clock page opens.
Содержание PTP 850E
Страница 1: ...User Guide PTP 850E System Release 10 9 ...
Страница 48: ...Chapter 2 Getting Started PC Setup phn 3963_008v000 Page 2 5 Figure 10 Internet Protocol Properties Window ...
Страница 502: ...Chapter 19 Alarm Management and Troubleshooting CLI Performing Diagnostics CLI phn 3963_008v000 Page 19 29 ...