Chapter 14: Radio Configuration (CLI)
Configuring and Viewing Radio PMs and Statistics (CLI)
phn-3963_008v000
Page 14-10
Table 75
Signal Level Threshold CLI Parameters
Parameter
Input Type
Permitted Values
Description
threshold
Variable
1e -6
1e -7
1e -8
1e -9
1e -10
The BER level above which a Signal Degrade
alarm is issued for errors detected over the
radio link.
The following command sets the Signal Degrade threshold at 1e-7:
radio [2/1]>modem signal-degrade set threshold 1e-7
Configuring the MSE Thresholds and Displaying the MSE PMs
(CLI)
To configure the MSE (Mean Square Error) threshold, enter the following command:
radio [x/x]>modem set mse-exceed threshold <threshold>
To display the currently configured MSE threshold, enter the following command:
radio [x/x]>modem show threshold-mse-exceed
Table 76
MSE CLI Parameters
Parameter
Input Type
Permitted Values
Description
threshold
Number
-99 - -1
The MSE threshold.
To display MSE (Mean Square Error) PMs in 15-minute intervals, enter the following command:
radio [x/x]>modem pm-mse show interval 15min
The following is a partial sample output of the
modem pm-mse show interval 15min
command: