11-1 Wiring Schematics
450 LXi
Owner Manual
~ 11-1-87 ~
Rev. “C”
Wiring Schematic 0095819 - 120Vac, Power Distribution/EMS, Floorplan B - Page 1 of 2
W/EMS,FPLB
BT
10/03/05
2
1
FULL
M450LXI
0095819
BT
08/11/05
SCHEMATIC,WRG,120VAC POWER DISTRIBUTION
13131L
INACTIVATES NOS.
LET.
WAS
REVISIONS
DR.
APP.
CCN
SCALE
BLUE BIRD CORPORATION
FORT VALLEY GEORGIA, U.S.A.
CCN
DR.
APP.
BY
BY
D
PAGE
__OF__
1
2
3
4
5
A
B
C
D
E
F
G
H
6
7
CONFIDENTIAL
The information hereon is confidential
business information and may not be copied
or used for any purpose unless permission
is expressly granted in writing by
Blue Bird Body Company.
Copyright 2002
Blue Bird Body Company
All rights reserved
WAS
LET.
REVISIONS
DR.
APP.
CCN
SHORE
GND
N
L2
L1
POWER
240VAC
50A
CB1 80A
CB2 80A
GENERATOR ENCLOSURE
GENERATOR
20KW
120/240VAC
60 HZ
CB1 80A
CB2 80A
L1
L2
N
GND
MAIN
CT1
POWER CORD
REEL
N
L2
L1
N
L2
L1
L1
L2
N
WHOLE HOUSE
SURGE
3
2
1
SHORE-L1
SHORE-L2
SHORE-N
GEN-L1
GEN-L2
GEN-N
2
1
3
4
6
5
5
6
4
80A/POLE
120/240VAC
ITS-75C
TRANSFER SWITCH
TIME DELAY BOARD
CB1
50A
ENERGY MANAGEMENT
UTIL-L1
UTIL-N
INVERTER-1
BYPASS
INV1-N1
INV1-L1
20A
20A
20A
CB6-B
CB6-A
20A
20A
20A
CB3-B
CB4-A
CB4-B
SWITCH
SYSTEM - PANEL 1
GEN-N
GEN-L2
GEN-L1
GND
12V
IGNITION
SWITCH
ARMREST
INDICATES SHORELINE PLUG
CONNECTED WITH IGNITION
SWITCH ON.
XFR-L1
XFR-L2
XFR-N
CB5
50A
20A
CB7-B
CB7-A
20A
CB8-A
INV-LC1-N1
CT1-1
CT1-2
SWITCH
BYPASS
UTIL-L2
INV2-L2
UTIL-N
INV2-N2
INVERTER-2
INV-LC2-N2
INV-LC2-L2
UTIL-N
UTIL-L1
UTIL-N
UTIL-L2
S1-C
S1-D
S2-B
S2-A
20A
20A
20A
CB2-B
CB3-A
CB2-A
20A
CB8-B
N
G
RLY#4
RLY#2
RLY#3
J4
2
3
1
RLY#5
RLY#6
6
5
4
3
1
J2
2
12V
GND
GEN RUN
1
2
2
1
J3
J1
HI-POT
TEST
CURRENT
SENSOR
ENERGY
MANAGEMENT
CONTROL
ELECTRONICS
HVAC
THERMOSTAT
CONTROL RELAYS
1A, 24VDC
SENSOR
CURRENT
6
CB4-B
CB2-A
CB2-B
CB3-B
CB3-A
CB2-A
CB4-A
CB2-B
CB3-A
CB3-B
CB4-A
CB4-B
MANAGEMENT
ELECTRONICS
J1
12V
GND
1
2
J4
TEST
HI-POT
ENERGY
CONTROL
1
2
20A
20A
20A
20A
20A
20A
20A
L2
L1
20A
20A
20A
20A
20A
SYSTEM - PANEL 2
ENERGY MANAGEMENT
RLY#5
RLY#6
2
3
1
5
4
1A, 24VDC
CONTROL RELAYS
THERMOSTAT
HVAC
J4
N
RLY#2
RLY#1
UTIL-L1
UTIL-N
UTIL-GND
INV-LC1-L1
UTIL-GND
INV-LC1-N1
INV-LC1-L1
SH 2
PNL1-CB4-B
SH 2
PNL1-CB4-A
SH 2
PNL1-CB3-B
SH 2
PNL1-CB3-A
SH2
PNL1-CB2-B
SH 2
PNL1-CB2-A
SH 2
PNL1-CB6-A
SH 2
PNL1-CB6-B
SH 2
PNL1-CB7-A
SH 2
PNL1-CB7-B
SH 2
PNL1-CB8-A
SH 2
PNL1-CB8-B
SH 2
SH 2
SH 2
SH 2
SH 2
PNL3-CB4-B
PNL3-CB4-A
PNL3-CB3-B
PNL3-CB3-A
PNL3-CB2-B
SH 2
SH 2
PNL3-CB2-A
PNL2-CB4-A
SH 2
SH 2
SH 2
SH 2
SH 2
PNL2-CB3-B
PNL2-CB3-A
PNL2-CB2-B
PNL2-CB2-A
PNL2-CB4-B
AC POWER DISTRIBUTION PANEL
1
2
CT1-1
CT1-2
UTIL-L2
HVAC
THERMOSTAT
CONTROL RELAYS
1A, 24VDC
J4
RLY#5
CT2-2
CT2-1
4
5
1
3
2
RLY#6
2
1
CONTROL
HI-POT
TEST
J4
2
1
GND
12V
J1
ELECTRONICS
MANAGEMENT
6
CURRENT
SENSOR
INV-LC1-N1
30A
CB1
30A
CB1
RLY#2
SYSTEM - PANEL 3
ENERGY MANAGEMENT
CT3
RLY#1
KIT A/C
BATH A/C
THERMOSTAT
THERMOSTAT
THERMOSTAT
BED A/C
THERMOSTAT
FRT A/C
INV-LC1-L1
S1-A
S1-B
S2-D
S2-C
SAFELINE
SHORE-L1
SHORE-N
SHORE-L2
SHORE-N
F2
1A
F1
1A
00-00912-000
00-00912-000
INV-UTIL2-N2
INV-UTIL2-L2
BYPASS
OFF
INV
INV
OFF
BYPASS
INV
OFF
BYPASS
INV
OFF
BYPASS
OFF
INV
BYPASS
OFF
INV
BYPASS
INV
BYPASS
OFF
INV
OFF
BYPASS
INV-UTIL1-N1
INV-UTIL1-L1
G
G
N
INV1-N1
INV1-L1
INV-LC2-L2
INV-LC2-N2
UTIL-L1
UTIL-L2
UTIL-N
SHORE-L1
SHORE-L2
SHORE-N
GND
CT2
AC IN
HOT 1
HOT 2
AC IN
BATTERY
BANK
24V
HOT 1
AC OUT
HOT 2
AC OUT
GND
NEUT
OUT
INV2-N2
INV2-L2
INVERTER
NEUT
NEG
BATT
POS
BATT
IN
INVERTER #2
INV-UTIL2-N2
INV-UTIL2-L2
HOT 1
AC IN
NEUT
AC IN
HOT 2
BANK
AC OUT
INV1-N1
INV1-L1
GND
BATT
NEG
24V
BATTERY
BATT
POS
INVERTER
NEUT
OUT
AC OUT
HOT 1
HOT 2
IN
INVERTER #1
INV-UTIL1-N1
INV-UTIL1-L1
30A
CB3
INV-1
30A
CB4
INV-2
INV1-L2
INV1-N2
UTIL-GND
UTIL-GND
ELEC BAY HEAT
COOKTOP
KITCHEN FLR HT
AIR COMPRESSOR
KITCHEN A/C
BATH FLR HEAT
BATH A/C
WASHER
WATER HEATER
ENGINE BLOCK HEAT
VOLTMETER-2
BED/BATH RCPT
PILOT RCPT
BATH LIGHT
KITCHEN RCPT
BEDROOM A/C
BAY GFI RCPT,
ROADSIDE
SLIDEOUT RCPT
MICROWAVE
A/V RCPT
DINETTE LGT
REFRIGERATOR
FRONT A/C
PRIV BATH LT,
RCPT, CO-PILOT
RCPT
BAY RCPT,CURB
SIDE
GIRARD AWNINGS
CB4
20A
CB3
20A
ENCL
BLOWER
MOTOR
GENERATOR
RADIATOR
BLOWER
MOTOR
BAY 5
INSTA-HOT
(INVERTER-2)
(INVERTER-1)
BB# 0092128
BB# 0092128
BB# 0092130
250A
F5
250A
F3
BB# 0090019
F4
250A
F6
250A
J3
J5 REMOTE
DISPLAY
REMOTE
DISPLAY
PANEL
BB#0092129
LOAD SHED
JUMPERS
LOAD SHED
RELAY SEQUENCE
4,3,6,5,2,1
LOCATED
IN EMS
PANEL
CT2
PANEL
IN EMS
CT3
LOCATED
DISPLAY
BB#0092127
PANEL
REMOTE
J3
DISPLAY
REMOTE
CT2-2
CT2-1
1,2,5,6
RELAY SEQUENCE
LOAD SHED
JUMPERS
LOAD SHED
F12 10A FUSE
BAY-2 LOAD
CENTER
CONTROL WIRING
CONTROL WIRING
CONTROL WIRING
CT3-2
CT3-1
CT3-1
CT3-2
DISPLAY
REMOTE
J3
BB#0092127
PANEL
DISPLAY
REMOTE
CENTER
BAY-2 LOAD
F13 10A FUSE
JUMPERS
RELAY SEQUENCE
5,2,3,6
LOAD SHED
LOAD SHED
CONTROL WIRING
LOCATION
BEDROOM
BEDROOM
LOCATION
LOCATION
BAY-5R
BAY-5R
LOCATION
LOCATION
BEDROOM
LOCATION
BAY-5L
LOCATION
NOSE BAY
TRANSFER SWITCH OPERATION:
1. TRANSFER SWITCH CONTROLLER IS LOOKING FOR THE GENERTOR INPUT
i.e. GENERATOR SOURCE PRIORITY.
TURNED OFF.
POWER INPUT IS IGNORED UNTIL THE GENERATOR POWER IS
IF THE GENERATOR INPUT IS DETECTED, THEN THE SHORE
2.
NOTE: THIS TRANSFER SWITCH IS CONNECTED AS A 240VAC SPLIT
PHASE CONFIGURATION. THE TWO 120VAC PHASE LOADS MUST
BE BALANCED. IF THE LOAD ON ONE PHASE IS LARGER THAN
THE OTHER PHASE, THEN THE VOLTAGE ON THE PHASE WITH
THE LARGER LOAD WILL DECREASE. THE VOLTAGE ON THE
PHASE WITH THE LIGHTER LOAD WILL INCREASE PROPORTIONALLY.
IF THE IMBALANCE IS LARGE, THEN EQUIPMENT COULD BE
DAMAGED DUE TO OVERVOLTAGE OR MOTORS COULD BE DAMAGED
DUE TO LOW VOLTAGE.
BELOW FLOOR
120V EQUIPMENT LOCATIONS
120V EQUIPMENT LOCATIONS
ABOVE FLOOR
INV
GEN
ALARM
SAFELINE
SHORE
VOLTMETER
AMMETER
PANEL
CONTROL
REMOTE
INVERTER
FUEL
TANK
TANK
FUEL
GEN
RAD
1&2
BAY-3R
BAY-2R
BAY-4R
BAY-5R
BAY-1R
BAY-4L
BAY-3L
BAY-2L
BAY-1L
PLUMBING
BAY
BAY-5L
SLIDEOUT
CONTROLLER
BAY DC
LOAD CENTER
AC POWER
DISTRIBUTION
PANEL
POWER
CORD
REEL
SHORE
HOUR
METER
HR-MTR
HR-MTR
CENTER
BAY-2 LOAD
F11 10A FUSE
ENERGY
MANAGEMENT
PANELS 1,2,3
AC RELAY
PANEL
GENERATOR
LOGIC
CONTROLLER
DRIVERS
ELECTRICAL
BAY
AIR
LEVELING
SYSTEM
NOTE 2: EMS PANEL-1 LOAD SHEDS
ONLY WHEN CONNECTED
TO 30A SERVICE.
L1-NEUTRAL OK
L1-L2 OK
L1-GND OK
NEUTRAL-GND
PROBLEM
PANEL INDICATORS
FIRST SOURCE PRIORITY
NOTE 1:
INVERTER BYPASS SWITCHES HAVE THREE POSITIONS,
BYPASS: PROVIDES UTILITY POWER TO THE 30A LOAD
CENTERS; i.e. INVERTER OUTPUT IS BYPASSED.
USED IF INVERTER FAILS.
POWER FROM THE 30A LOAD CENTERS.
OFF: DISCONNECTS UTILITY POWER & INVERTER
USED IF REQUIRED TO SERVICE LOAD CENTER.
POWER IS PRESENT, THEN OUTPUT IS UTILITY
INTERNAL TRANSFER SWITCH. IF UTILITY
INV: PROVIDES UTILITY POWER TO THE INVERTER'S
POWER. IF UTILITY POWER IS NOT PRESENT
THEN OUTPUT POWER IS FROM THE INVERTER.
NOTE 3
NOTE 3
ON FOR EMS PANEL TO
SENSE 30A SERVICE.
CB3-A & CB6-A MUST BE
NOTE 3:
NOTE 2.
SUPPRESSOR
NOTE 2:
ADD 12 GA BLACK JUMPER WIRE BETWEEN L1 AND L2.
(JUMPER WIRE USE BLACK 12 GA FROM 12-2 W/G BB#4051777)
BATTERY CHARGER
VOLTMETER-1/DRYER
DINN LT,REC
A
A
A
A
CHANGE LOAD CENTER PART NUMBERS & DIP SWITCH SETTING
BT
BT
02/06/06
13177V
00-00549-000
BB# 0071744
S1-1
S1-2
S1-3
S1-4
S1-5
S1-6
S1-7
S1-8
ON
OFF
OFF
ON
S1-8
S1-7
S1-6
S1-5
S1-4
S1-3
S1-2
S1-1
S1-1
S1-2
S1-3
S1-4
S1-5
S1-6
S1-7
S1-8
ON
OFF
Содержание 450 LXi
Страница 1: ......
Страница 11: ...450 LXi Owner Manual Rev C NOTES...
Страница 37: ...450 LXi Owner Manual Rev C NOTES...
Страница 51: ...450 LXi Owner Manual Rev C NOTES...
Страница 59: ...450 LXi Owner Manual Rev C NOTES...
Страница 63: ...450 LXi Owner Manual Rev C NOTES...
Страница 103: ...450 LXi Owner Manual Rev C NOTES...
Страница 129: ......
Страница 165: ...450 LXi Owner Manual Rev C NOTES...
Страница 171: ...4 14 Appliances 450 LXi Owner Manual 4 14 6 Rev C 4 14 5 Touch Control Panel...
Страница 188: ...450 LXi Owner Manual 4 14 Appliances Rev C 4 14 23 4 14 13 Auto Touch Guide...
Страница 207: ...450 LXi Owner Manual Rev C NOTES...
Страница 218: ...450 LXi Owner Manual 4 16 Audio Video Components Rev C 4 16 11 4 16 2 12 Location of Controls Illuminate Remote Control...
Страница 219: ...4 16 Audio Video Components 450 LXi Owner Manual 4 16 12 Rev C...
Страница 221: ...4 16 Audio Video Components 450 LXi Owner Manual 4 16 14 Rev C...
Страница 244: ...450 LXi Owner Manual 4 16 Audio Video Components Rev C 4 16 37...
Страница 248: ...450 LXi Owner Manual 4 16 Audio Video Components Rev C 4 16 41...
Страница 250: ...450 LXi Owner Manual 4 16 Audio Video Components Rev C 4 16 43 4 16 3 5 Basic Controls...
Страница 253: ...4 16 Audio Video Components 450 LXi Owner Manual 4 16 46 Rev C...
Страница 267: ...4 16 Audio Video Components 450 LXi Owner Manual 4 16 60 Rev C 4 16 4 12 Location of Controls...
Страница 268: ...450 LXi Owner Manual 4 16 Audio Video Components Rev C 4 16 61...
Страница 314: ...450 LXi Owner Manual 4 16 Audio Video Components Rev C 4 16 107 Other Audio Visual Equipment...
Страница 320: ...450 LXi Owner Manual 4 16 Audio Video Components Rev C 4 16 113...
Страница 369: ...450 LXi Owner Manual Rev C NOTES...
Страница 373: ...4 17 Electronic Step 450 LXi Owner Manual 4 17 4 Rev C NOTES...
Страница 375: ...450 LXi Owner Manual Rev C NOTES...
Страница 411: ...450 LXi Owner Manual Rev C NOTES...
Страница 459: ...This Page Was Intentionally Left Blank...
Страница 527: ...5 4 Generator Maintenance Service 450 LXi Owner Manual 5 4 24 Rev C NOTES...
Страница 531: ...450 LXi Owner Manual Rev C NOTES...
Страница 535: ...450 LXi Owner Manual Rev C NOTES...
Страница 556: ...450 LXi Owner Manual 10 1 Where to Go for Service Rev C 10 1 9...
Страница 557: ...450 LXi Owner Manual Rev C NOTES...