3.8
On-line command processing via serial or field bus interface
This mode is available if the unit has a serial interface RS 232 or RS 485
or a field bus interface (e.g. Interbus-S or Profibus-DP) installed in
adapter slot OPT.1.
Only available for
some unit variants;
see chapter 3.1.
In this mode, single movement commands and other commands are
transmitted to the controller and executed immediately. A comprehensive
command set is available for this purpose.
NOTE
The following parameters must have been set (see chapter 3.3.1):
– For serial interface, operating mode with parameter P00 = 2
– For CAN-Bus, operating mode with parameter P62
– Network address with parameter P60 (only for RS 485, Profibus-DP,
CAN-Bus and SUCONET)
– Baud rate with parameter P61 (only for serial interface, Interbus-S and
CAN-Bus)
If “run” is displayed in the status display, on-line command processing is
enabled.
Start by activating the power controller with the INITDRIVE command
before executing any movement commands.
ATTENTION
The parameters set via the front panel are used for the basic
settings of the unit. Some of these settings can be changed by
on-line command processing.
The transmitted values will be lost when switching off.
Reference documentation
On-line command processing mode is described in the following do-
cumentations:
–
On-line Command Processing and Upload/Download via Serial
Interface
–
On-line Command Processing via CAN-Bus
–
On-line Command Processing via Interbus-S
–
On-line Command Processing via Profibus-DP
–
On-line Command Processing via SUCONET
Description of the P69 parameter
If the parameter P69 = 1, a manual movement via I/O (see chapter 3.4)
and status output via outputs (see chapter 4.1) is possible.
During a manual movement (signal AUTOM = 0), only read commands
can be processed.
On-line
command
processing
Operation
WDP3-01X Ident. no.: 00441109760
3-23
Содержание WDP3-01X
Страница 4: ......
Страница 8: ...Page 7 Index 7 1 8 Corrections and additions 8 1 Table of contents WDP3 01X Ident no 00441109760 ...
Страница 52: ...Installation 2 26 WDP3 01X Ident no 00441109760 ...
Страница 92: ...Customer service 5 2 WDP3 01X Ident no 00441109760 ...
Страница 108: ...Appendix 6 16 WDP3 01X Ident no 00441109760 ...
Страница 114: ...Corrections and additions 8 2 WDP3 01X Ident no 00441109760 ...