Maintenance
Operating instructions
29
Maintenance
Maintaining the device
The device is maintenance-free.
Changing the bulbs
The device is fitted with maintenance-free LED lighting.
The bulbs have a service life of approximately 30,000
operating hours.
Ø
If you have any problems, contact your berbel dealer
or customer services.
Changing the filter filling (hybrid and
recirculated air filters)
Replace the filter filling in accordance with the following
table:
Usage
Time interval
Little or
occasional
use
At least every 24 months or when there
are odours in the exhaust air.
Daily or
heavy use
At least every 12 months or when there
are odours in the exhaust air.
WARNING
Risk of falling when changing the filter.
Ø
Use a stable step-ladder.
WARNING
Risk of injury from hot parts.
Ø
Ensure that the cooking hob and the
device have cooled down.
Ø
Let all parts cool down before
beginning work.
WARNING
Risk of injury from falling parts.
Ø
Ensure that no-one is beneath the
working area when working on the
device.
ATTENTION
Damage caused by falling parts.
Ø
Protect areas and devices (e.g.
cooled cooking hob) underneath the
working area against damage, e.g.
using thick cardboard.
The filter must be easily accessible. All panels abovue
the front panel with the control panel of the device must
be removed.
Ø
Remove all the screens and other attached
modifications. The filter must be easily accessible.
The filter is easily accessible.