Installing the device
58
Installation instructions
Ø
Seat the filter from above onto the guides in the fan
housing.
Ø
Make sure that the filter is inserted correctly.
Ø
Push the exhaust pipe onto the filter collar.
Ø
Seal the transition between the exhaust pipe and the
guide with the help of sealing tape.
Ø
Ensure that the exhaust pipe is correctly fitted.
Install the other parts
After installation, fit the removed parts as follows:
Insert the capillary trap
Ø
Make sure that the capillary trap is completely dry
before re-inserting.
Ø
Ensure that the words "Front" on the capillary trap
are pointing to the front side of the device.
Ø
Insert the capillary trap into the device by guiding it
with both hands into the mounting slot (1.)
Ø
Push the capillary trap upwards into place (2.).
The capillary trap snaps into place with an audible
sound.