42
STP
Stop input open (actuated)
SL7 Ts 27 & 28
LS
Light barrier input open (actuated)
SL7 Ts. 29 & 30
SE1
Safety input 1 - none 8,2kΩ detected / OES error SL8 Ts 32 & 35
SE2
Safety input 2 - none 8,2kΩ detected / OES error SL8 Ts 33 & 36
E-A
Limit switch open detected
E-Z
Limit switch Closed Detected
####
No learning trips carried out yet
?
End positions / reference positions are searched
for after voltage is switched back on.
*
Hold-up time is running out
13.4.
Troubleshooting instructions
The DCM 21-i control unit make troubleshooting much easier for the
installer. The display not only shows you the currently activated inputs, but the
controls also have a memory, which stores the last 10 malfunctions (software)
see instruction point 13.1. and the last 50 activations (safety inputs etc.) – see
instruction point 13.2. incl. time display.
Proceed as follows to read out the currently actuated inputs:
Press the
"Escape/Menu" key repeatedly until the display shows "Last com-
mands". Now press the "Escape/Menu" key again.
Now the current status of the motor is shown in the first line of the display. The
second line of the display shows you the currently activated/operated inputs.
Indicator
Significance of the indi-
cator
Potential malfunctioning
Cause & remedy
Z1
&
Z2
The contacts of the hall
sensors, which are in-
stalled in the motor,
are active during en-
gine operation. They
flash continually in that
period.
In downtime, it has no
importance to know if
they are
active or not.
If they stopped flashing:
►
The motor is defective
Replace the motor
►
The wire of the hall sensor is damaged
Repair the wire / replace the
motor
REF
The Reed contact which
serves as a reference
point should shortly
flashes by each travel.
It stopped flashing:
►
Magnet on the gear rack missing
Fix a new magnet
►
The Reed contact is defective
43
Repair the wire / replace it
►
The wire of the Reed contact is damaged
Repair the wire or replace the Reed
contact
It flashes continuously
►
The Reed contact is not connected
Connect the Reed contact
►
The Reed contact is defective
Replace it
A
B
C
D
The inputs, which are
operated with poten-
tial-free buttons, flash
when they are active.
Though an external button
has been pressed, they do
not flash no more
►
The circuit of the button is discontinuous
Repair the wire / replace it
►
The button is defective
Replace the button
They flash continuously
►
The wire is damaged
Repair the wire / replace it
►
The button is defective
Replace the button
►
A commutator has been set up instead of
a push-button
Set up a push-button
STP
The stop input flashes
when the terminals 27
& 28 are not intercon-
nected
(Emergency stop
active)
Though the emergency
stop switch has been acti-
vated, the sign does not
flash.
►
The wire is damaged
Repair the wire / replace it
►
Several emergency-stop switches have
been connected in parallel
Connect them in series
Though the emergency
stop switch has not been
activated,
It flashes continuously
►
The wire of the emergency stop switch is
defective
Repair the wire / replace it
►
the opening contact and the closing con-
tact of the emergency stop switch inter-
changed
Use a rest contact
LS
The input of the light
barrier flashes if the
terminals 29 & 30 are
inter-connected. (Light
barrier active)
Though the light beam has
been interrupted, they do
not flash.
►
The wire is pulled
Repair the wire / replace it
►
Several light barriers have been connected
in parallel
Connect them in series
Though the light beam has
not been interrupted, they
flash
continuously.
►
The wire of the safety contact edge is de-
fective
Repair the wire / replace it
►
The opening contact and the closing con-
Содержание 47-21-i
Страница 9: ...D E U T S C H 9 3 3 S Sc ch ha al lt tb bi il ld d ...
Страница 13: ...D E U T S C H 13 ...
Страница 48: ......
Страница 57: ...E N G L I S H 9 3 3 C Ci ir rc cu ui it t d di ia ag gr ra am m ...
Страница 61: ...E N G L I S H 13 ...
Страница 96: ......
Страница 109: ...F R A N Ç A I S E 13 ...
Страница 144: ......
Страница 153: ...E S P A Ñ O L 9 3 3 E Es sq qu ue em ma a d de e c co on ne ex xi io on ne es s ...
Страница 157: ...E S P A Ñ O L 13 ...
Страница 192: ......
Страница 201: ...N E D E R L A N D S 9 3 3 Schakelschema ...
Страница 205: ...N E D E R L A N D S 13 ...
Страница 240: ......
Страница 249: ...P O L S K I E 9 3 3 S Sc ch he em ma at t p po oł łą ąc cz ze eń ń ...
Страница 253: ...P O L S K I E 13 ...
Страница 288: ......