To decide whether your gate system is DIN left or DIN right, please refer
to
chapter 10 DIN LEFT & DIN RIGHT to find out which DIN your gate
system has.
NOTE: By changing the gate type, all menu configurations are set to the
default settings.
9.3.
Radio
This menu option allows you to:
Program radio
Program / teach-in new remote controls
Delete radio
Delete individual or all remote-control codes
Radio level
Displays strength of signal from remote controls &
displays active remote controls.
Amount acc.
Displays the total number of remote controls
connected to the system
System
Displays the programmed radio system (the radio
system of the first hand-held transmitter is taken
over)
9.4.
Sensor
In this menu item, you can select which position detection devices are to
be used.:
Hall-sensors
Hall-sensors with reference switch
9.5.
A Impulse
In this menu item you can determine the mode of action of input A:
Impulse (Open – Stop – Close – Stop …)
Limit switch (Limit switch OPEN with DIN-Left or limit switch CLOSE
with DIN-Right)
25
9.6.
B Opening
In this menu item you can determine the mode of action of input B:
Stop panic (Open-Stop-…)
Stop no panic (Open-Open-…)
Deadman (Press-and-hold travel: the gate opens only as long as the
respective button is pressed)
Limit switch ((limit switch closed with DIN left or limit switch open
with DIN right)
9.7.
C Closing
In this menu item you can determine the mode of action of input C:
Stop panic (Close-Stop-…)
Stop no panic (Close-Close-…)
Deadman (Press-and-hold travel: the gate closes only as the corre-
sponding button is pushed)
Limit switch (limit switch closed with DIN left or limit switch open
with DIN right)
9.8.
D Partial-opening (PO)
In this menu item you can determine the mode of action of input D:
Stop panic (PO-Stop-Close-Stop…)
Stop no panic (PO-PO-…)
Auto closing OFF (Automatic closing turned off.)
Limit switch (Limit switch OPEN with DIN-left or limit switch CLOSED
with DIN-Right.)
Furthermore, the percentage of the partial opening’ travel distance (as
compared to the total travel distance) must be set here. It must be less
than 100%.
If input D is permanently activated and the gate is closed from end posi-
tion OPEN with automatic closing and no limit switch is set, the system
only closes up to the partial opening position (personnel entrance).
Содержание 47-21-i
Страница 9: ...D E U T S C H 9 3 3 S Sc ch ha al lt tb bi il ld d ...
Страница 13: ...D E U T S C H 13 ...
Страница 48: ......
Страница 57: ...E N G L I S H 9 3 3 C Ci ir rc cu ui it t d di ia ag gr ra am m ...
Страница 61: ...E N G L I S H 13 ...
Страница 96: ......
Страница 109: ...F R A N Ç A I S E 13 ...
Страница 144: ......
Страница 153: ...E S P A Ñ O L 9 3 3 E Es sq qu ue em ma a d de e c co on ne ex xi io on ne es s ...
Страница 157: ...E S P A Ñ O L 13 ...
Страница 192: ......
Страница 201: ...N E D E R L A N D S 9 3 3 Schakelschema ...
Страница 205: ...N E D E R L A N D S 13 ...
Страница 240: ......
Страница 249: ...P O L S K I E 9 3 3 S Sc ch he em ma at t p po oł łą ąc cz ze eń ń ...
Страница 253: ...P O L S K I E 13 ...
Страница 288: ......