30
9.19.
Speed
In this menu item you can individually set the speed, at which the gate
runs "OPEN" or "CLOSED". This is a percentage voltage setting, so the
setting is not completely linear.
9.20.
Soft start
In this menu item you can set the speed at which the drive always starts;
the duration of the soft start can also be set here.
9.21.
Soft-run OPENING
CAUTION!
For safety reasons, a minimum run-out distance of 60cm must be pro-
grammed! This corresponds to the percentages given in the table under
point 9.22.
In this menu item you can set the speed, at which the drive in the soft
stop direction OPEN will run out, and the length of the soft stop can also
be set here proportionally.
9.22.
Soft run CLOSING
CAUTION!
For safety reasons, a minimum run-out distance of 60cm must be pro-
grammed! This corresponds to the percentages given in the table below.
In this menu item you can set the speed at which the drive in the soft stop
direction CLOSE runs out, and the length of the soft stop can also be set
here as a percentage.
IS* at the opening in m
1
2
3
4
5
6
7
8
9
Min. length of smooth run 60% 30% 20% 15% 12% 10% 9% 8% 7%
IS* at the opening in m
10
11
12
13
14
15
16 17 >17
Min. length of smooth run 6% 5%
5%
5%
4%
4% 4% 4% 4%
*IS = Intermediate space
31
9.23.
Delete data
This menu item allows you to delete the following data:
1: -----
No deletion
2: Forces
Deletion of memorized forces
3: Dis
Forces
Deletion of memorized end of travel positions and
forces
4: Configurations Deletion of all memorized configurations
9.24.
Cycle counter
This menu item is a pure display menu, here you can read the number of
runs made so far. This value cannot be deleted or reset.
9.25.
Version
This menu item is a pure display menu, here you can see which software
version is programmed in the control unit.
9.26.
Motor parameter
This menu item is a display menu for the motor parameter.
9.27.
Emergency function
In this menu item you can activate or deactivate the emergency function
(see section 7.5.: Button inputs A-D). After a RESET of the control, the
emergency function is inactive.
9.28.
Restart
In this menu item you can activate or deactivate the restart.
If an active command is detected at inputs A-D after the voltage has been
switched on, the controls start the motor to assume the desired status /
end position. If an additional safety input is detected as active, the start to
the end position is not carried out.
Input A
With automatic closing – Starts opening the
gate and keeps the gate open
Input B
Starts opening in the mode "Open without
stop".
Input C
Starts closing in the mode "Close without
stop".
After a RESET of the control, the restart is inactive.
Содержание 47-21-i
Страница 9: ...D E U T S C H 9 3 3 S Sc ch ha al lt tb bi il ld d ...
Страница 13: ...D E U T S C H 13 ...
Страница 48: ......
Страница 57: ...E N G L I S H 9 3 3 C Ci ir rc cu ui it t d di ia ag gr ra am m ...
Страница 61: ...E N G L I S H 13 ...
Страница 96: ......
Страница 109: ...F R A N Ç A I S E 13 ...
Страница 144: ......
Страница 153: ...E S P A Ñ O L 9 3 3 E Es sq qu ue em ma a d de e c co on ne ex xi io on ne es s ...
Страница 157: ...E S P A Ñ O L 13 ...
Страница 192: ......
Страница 201: ...N E D E R L A N D S 9 3 3 Schakelschema ...
Страница 205: ...N E D E R L A N D S 13 ...
Страница 240: ......
Страница 249: ...P O L S K I E 9 3 3 S Sc ch he em ma at t p po oł łą ąc cz ze eń ń ...
Страница 253: ...P O L S K I E 13 ...
Страница 288: ......