Product overview
CX1500-M510, CX1500-B510
31
Version: 1.0
Index
Sub-index Name
Type
Attribute
Mapping
Default
value
Meaning
0x1400
0
Number of
elements
Unsigned8 ro
N
5
Communica
tion
parameters
for the first
receive
PDO. Sub-
index 0:
number of
following
parameters
1
COB-ID
Unsigned32 rw
N
0x000002x
y,
xy=Node-ID
COB-ID
(Communic
ation Object
Identifier)
RxPDO1
2
Transmissi
on Type
Unsigned8 rw
N
255
Transmissi
on type of
the PDO
3
Inhibit Time Unsigned16 rw
N
0
Present for
reasons of
backwards
compatibilit
y, but not
used in the
RxPDO.
4
CMS
Priority
Group
Unsigned8 rw
N
-
Present for
reasons of
backwards
compatibilit
y, but not
used.
5
Event
Timer
Unsigned16 rw
N
0
Event-
Timer.
Watchdog
time
defined for
monitoring
reception of
the PDO.
Sub-index 1 (COB-ID): The bottom 11 bits of the 32 bit value (bits 0-10) contain the CAN identifier. The MSB
(bit 31) indicates whether the PDO exists currently (0) or not (1). Bit 30 indicates whether an RTR access to
this PDO is permissible (0) or not (1). Changing the identifier (bits 0-10) is not allowed while the object exists
(bit 31=0). Sub-index 2 contains the type of the transmission (see introduction to PDOs).
Communication parametersfor the 2nd RxPDO