Product overview
CX1500-M510, CX1500-B510
11
Version: 1.0
Parallel operation of several identical or different master connections is also possible, Mixed operation of
master and slave connections is also not a problem. A CX system can thus also assume the functionality of
an intelligent gateway between different fieldbuses, receiving data from a fieldbus, processing them via a
program and then feeding them into another fieldbus.
The performance data of the CX fieldbus master modules are nearly identical to those of the Beckhoff PC
fieldbus cards, except for the fact that the CX variants are always single-channel types. The number of
slaves that can be connected is only limited by the respective bus system. The use of master or slave
connections enables networking of several CX systems with each other via the fieldbus level. In contrast to
networking via Ethernet, strictly deterministic data transmission can be achieved in this case.
CX fieldbus modules can be upgraded or exchanged in the field and can be connected to an existing CX
system via the PC104 system bus. The power supply of the fieldbus connections is also ensured via the
PC104 bus. Despite the ISA bus, no address switch is required for the address setting, since the modules
are assigned an address via internal setup. (The address must be selected by ordering the module)
The software integration of the fieldbus connections into the TwinCAT automation software is done in the
usual comfortable way: Scanning and detection of the modules, parameterization, configuration of the
connected I/O components as well as online diagnosis of the process and fieldbus status are carried out in
the familiar way through the TwinCAT System Manager.
2.2.1
Technical data CX1500-B510
Technical data
CX1500-B310
Fieldbus
CANopen
Transmission rate
10, 20, 50, 100, 125, 250, 500, 800, 1000 kBaud
Bus connection
Open-Style-Connector, 5-polig
Bus nodes
max. 127 slaves
Max. I/O-size
1536 Bytes Input / 1536 Byte Output
Interface to the CPU
16 bit ISA (PC104-Standard) / 2 kbyte DPRAM
Max. power consumption
1,8 W
Dimensions
38 mm x 100 mm x 91 mm
Weight
190 g
Operating temperature
0 °C ... +55 °C
Storage temperature
-25 °C ... +85 °C
Relative humidity
95% no condensation
Vibration/shock resistance
confirms to EN 60068-2-6 / EN 60068-2-27/29
EMC resistance burst /ESD
confirms to EN 61000-6-2 / EN 61000-6-4
Protection class
IP 20
2.2.2
Connections CX1500-M510 / B510
The connection to the CANopen bus is realized by a 5 pin open style connector.