![Beckhoff CX1500-B310 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/beckhoff/cx1500-b310/cx1500-b310_manual_2719532047.webp)
Product overview
CX1500-M510, CX1500-B510
47
Version: 1.0
Index
Meaning
0x2000
Digital inputs (function identical to object 0x6000)
0x2100
Digital outputs (function identical to object 0x6100)
0x2200
1-byte special terminals, inputs (at present no
terminals corresponding to this type are included in
the product range)
0x2300
1-byte special terminals, outputs (at present no
terminals corresponding to this type are included in
the product range)
0x2400
2-byte special terminals, inputs (at present no
terminals corresponding to this type are included in
the product range)
0x2500
2-byte special terminals, outputs (at present no
terminals corresponding to this type are included in
the product range)
0x2E00
7-byte special terminals, inputs (at present no
terminals corresponding to this type are included in
the product range)
0x2F00
7-byte special terminals, outputs (at present no
terminals corresponding to this type are included in
the product range)
3-byte special terminals, input data
3-byte special terminals, input data
Index
Sub-index Name
Type
Attribute
Mapping
Default
value
Meaning
0x2600
0
Number of
elements
Unsigned8 ro
N
Depending
on type and
fittings
Number of
available 3-
byte special
channels,
inputs
1
1
st
input
block
Unsigned24 ro
Y
0x000000
1
st
input
channel
...
...
...
...
...
...
...
0X80
128
th
input
block
Unsigned24 ro
Y
0x000000
128
th
input
channel
Example of special terminals with 3-byte input data (in the default setting): KL2502 (PWM outputs, 2 x 3
bytes)
3-byte special terminals, output data
3-byte special terminals, output data
Index
Sub-index Name
Type
Attribute
Mapping
Default
value
Meaning
0x2700
0
Number of
elements
Unsigned8 ro
N
Depending
on type and
fittings
Number of
available 3-
byte special
channels,
outputs
1
1
st
output
block
Unsigned24 rww
Y
0x000000
1
st
output
channel
...
...
...
...
...
...
...
0X80
128
th
output
block
Unsigned24 rww
Y
0x000000
128
th
output
channel