en_BA_OxE7
_PosCon3D.docx
9/64
Baumer Electric AG
17.07.2014 14:21/tof V1.01 ANW_81125407
Frauenfeld, Switzerland
GAP: Gap measurement
To perform gap measurement, select FUNCTION GAP in
the menu. In GAP the measurement type to be activated
is defined in the MEAS TYPE menu.
GAP
= Distance between the first
falling flank from the left and the
first falling edge from the right.
CENTER GAP
= Center between the first falling
flank from the left and the first
falling flank from right in relation
to the measuring axis of the
sensor.
GAP
CENTER GAP
GAP DEPTH
Minimum gap depth to be detected as an edge.
OBJECT
Selection of light or dark objects to optimize the
measurement results.
PRECISION
To achieve better precision and resolution, it is possible to
alternate between Standard, High and Very high by
filtering the output values.
FLEX MOUNT
If the sensor is mounted at an angle, FLEX MOUNT must
be activated and the reference surface must be taught in.
1. Activate FLEX MOUNT
2. Align and confirm sensor or reference surface
3. When all conditions are met (see table on right),
confirm by pressing Set for 2 seconds
4. Enter thickness of the auxiliary plate (if present)
Distance between sensor
and reference surface
Installation angle too large
Reference surface too
uneven
Reference surface too
small (<50 mm)
3c
Min. gap depth
Object
Reference