6.5.5
Switching output
The switching output can be adjusted as a point or a window and the switching points can be set, see Section
DIGITAL OUT.
The output is output as a push-pull signal active high or active low, depending on setting.
6.5.6
Alarm
The alarm output cannot be adjusted and is triggered by the following situations:
•
No object in the measuring range
•
No edge in the measuring range
•
Amplitude of the received signal is insufficient (e.g. in case of soiling)
It is output as a push-pull signal (active high).
6.5.7
Interface RS-485
During operation with RS485 no
more than 16 sensors may be connected to one bus.
When activating the RS485 interface, the analog output, the digital output and the alarm output are disabled.
See separate RS 485 manual.