WIDTH: Width measurement
To perform width measurement, select FUNCTION
WIDTH in the menu. In WIDTH the desired output is
selected in the MEAS TYPE menu.
WIDTH
= Distance between the first rising
flank from the left and the first
rising flank from the right.
CENTER WIDTH
= Center between the first rising
flank from the left and the first
rising flank from right in relation to
the measuring axis of the sensor.
WIDTH
CENTER WIDTH
OBJECT HEIGHT
Minimum height of the object to be measured.
OBJECT
Selection of light or dark objects to optimize the
measurement results.
PRECISION
To achieve better precision and resolution, it is possible to
alternate between Standard, High and Very high by
filtering the output values.
FLEX MOUNT
If the sensor is mounted at an angle, FLEX MOUNT must
be activated and the reference surface must be taught in.
1. Activate FLEX MOUNT
2. Align and confirm sensor or reference surface
3. When all conditions are met (see table on right),
confirm by pressing Set for 2 seconds
4. Enter thickness of the auxiliary plate (if present)
Distance between sensor
and reference surface too
long
Installation angle too
large
Reference surface too
uneven
Reference surface too
small (<50 mm)
3b
Min. object height
Object
Reference