en_BA_OxE7
_PosCon3D.docx
20/64
Baumer Electric AG
17.07.2014 14:21/tof V1.01 ANW_81125407
Frauenfeld, Switzerland
4.8 Practical zero point search
In case of angled installation, the zero point (0 mm) of the K axis shifts out of the center of the red visible laser
line.
4.9 Installation accessories
To ensure optimal mounting, various mounting brackets are available an as accessory. These brackets fit the
mounting holes of the sensor exactly. The sensor can be shifted and adjusted inside the mounting hole.
4.9.1
Mounting kit for standard installation Order no. 11120705
With the mounting bracket for standard installation, the sensor can be mounted quickly and easily at a 90°
angle to the reference surface.
Mounting kit 11120705
Contents of this set:
-
90° mounting bracket
-
Threaded plate
-
2x spherical head screw M4x35
-
1x Torx tool T20
-
NOTE
The "Edge L rise or Edge R rise" mode can be used as an aid to find the zero point.
Now an object is slowly pushed toward the presumed zero point. The zero point is
reached by the left rising edge of the object when the value 0 mm is shown on the
sensor display and the yellow LED switches.
Содержание PosCon3D