54/64
Baumer Electric AG
17.07.2014 14:21/tof V1.01 ANW_81125407
Frauenfeld, Switzerland
6.5 Interfaces and outputs
All sensor inputs and outputs which transmit measuring data are referred to as interfaces.
-
Analog current output, 4…20mA or 0…10V (automatic switchover)
-
Synchronization
-
Switching output push-pull
-
Alarm output push-pull
-
RS-485
6.5.1
Analog signal output
The sensor has an adaptive output. This means that the sensor recognizes automatically whether it should
deliver current or voltage. This is done by measuring the electrical load during startup, if the load is high
impedance (>10 kOhm) the voltage output is activated, otherwise the current output.
To change to the other analog mode (Current or voltage), the supply vVs of the sensor must be
switched off and on again.
6.5.2
Calculating the analog output signal in function Edge or Center
Using the following formulas, the measuring values in mm can be converted into the analog output signal:
= 12
+
∗ 0.1
! = 5 # +
∗ 0.05
0
5
10
15
20
25
-80
0
80
O
u
tp
u
t
a
n
a
lo
g
m
A
/V
Distance from the center in mm
Analog output
Edge/Center width/Center gap
mA
Volt