en_BA_OxE7
_PosCon3D.docx
35/64
Baumer Electric AG
17.07.2014 14:21/tof V1.01 ANW_81125407
Frauenfeld, Switzerland
5.8.1
No
"Deactivate" deactivates FLEX MOUNT, the sensor can be remounted in standard installation.
When FLEX MOUNT is not activated, 0° angle and 250 mm distance are set.
The angle symbol
disappears from the display.
5.8.2
Yes
FLEX MOUNT is activated in this menu item when the sensor is to be mounted at an angle.
Next "Place the reference" is output by the sensor and then the sensor must be aligned to the reference
surface (or to the auxiliary plate if there is not a reference surface).
Auxiliary plate
To compensate unevenness of the reference surface and to increase accuracy, an even temporary auxiliary
plate can be used for this process, which is placed on the reference surface during teaching-in and removed
after the process.
This plate should be as even as possible and must cover at least 50 mm of the laser beam. It must be
ensured that the plate is parallel to the reference surface below it.
The thickness of this plate is not important as long as it is within the measuring field of the sensor.
Auxiliary plate during the
teach-in process
Reference surface
uneven
M
K
Left
Right
Minimum length of reference
surface or auxiliary plate
Distance between
sensor and
reference
surface
THICKNESS REF
Note
The following menu items TEACH REF and THICKNESS REF must be completed
so that FLEX MOUNT can be activated.