Baumer Electric AG
17.07.2014 14:21/tof V1.01 ANW_81125407
Frauenfeld, Switzerland
4.4 Sensor alignment
As standard the sensor is mounted at a right angle (90°) to the reference surface or the object (standard
installation), but it can also be mounted at an angle of up to ±30° (angled installation).
To get the most accurate measurement results possible in angled installation, the inclination angle of the
sensor has to be taught in, see Section FLEX MOUNT.
The distance from the reference surface or the object must not exceed 250 mm on the measuring axis.
NOTE
To facilitate sensor alignment, the LIVE MONITOR can be used as an aid. LIVE
MONITOR continuously outputs the currently measured angle and the distance
from the reference surface.
NOTE
Angle deviations can affect measuring accuracy (see Section Alignment errors).