5.3 LIVE MONITOR
The installation conditions can be checked using the LIVE MONITOR. The sensor continuously measures the
angle and the distance from the optical axis to the measuring level and outputs the values. This makes
installation much easier and also points out installation errors.
LIVE MONITOR
15.7° 220mm
Measured angle in ° to
the reference surface
NOTE
An angle of 0° means that the sensor is at a right angle to the reference surface.
Distance to the
reference surface
Distance
Right
Left
Angle