en_BA_OxE7
_PosCon3D.docx
17/64
Baumer Electric AG
17.07.2014 14:21/tof V1.01 ANW_81125407
Frauenfeld, Switzerland
4.5.1
Definition of the measuring field with standard installation
The important terms "Left" and "Right" are to be regarded respectively from the viewpoint of the connector.
-37.5 mm
0 mm
12 mA / 5 V
+62.5 mm
18.25 mA / 8.12 V
2
5
0
m
m
0 mm
1
0
0
m
m
Measuring
field
X
Z
+37.5 mm
-62.5 mm
5.75 mA / 1.87 V
Blind region
Reference
point
The sensor measures objects and edges
at a distance of 150 … 250 mm (z axis)
and in the measuring range (x axis) from
-62.5 mm to +62.5 mm (at a distance of
250 mm).
The object must be within the measuring
field, i.e. the distance must not exceed
250 mm, but it can also be smaller.
Note
On the analog output:
For further explanations, see
Section "Function and definition“ -
> "Interfaces and outputs" ->
"Analog signal output".
M
e
a
s
u
ri
n
g
a
x
is
Right
Left