4.6 Angled installation
Compared to standard installation, the sensor can be mounted at an arbitrary inclination angle up to ±30°.
This is particularly useful when space conditions do not allow any other installation option. See also Section
FLEX MOUNT. The object must be within the measuring field.
4.6.1
Definition of the measuring field with angled installation
At the maximum allowable inclination angle of ±30°, the sensor measures objects and edges within the
measuring field defined below. The important terms "left" and "right" are to be regarded respectively from the
connector side of the sensor.
After activating the FLEX MOUNT function the axes M and K now represent the
measurement coordinate system and no longer the sensor axis. The measured value is now the distance from
one object-edge to the M-axis.
0 mm
0…-30°
+30…0°
0 mm
250 mm
K
M
Reference surface
Measuring
field
-73.0 mm
+54.6 mm
0 mm
0 mm
250 mm
K
M
Measuring
field
-68.8 mm
+57.3 mm
Example with -30° inclination
angle
Example with -20° inclination angle
Blind region
Blind region
Reference point
Reference point