5.10 DIGITAL OUT
With Pin 4 (out), the user has a configurable switching output
which can be defined as an individual switch point or as a window. Pin 4 is activated when the value (point or
window) is exceeded or not reached (active high or active low depending on the setting).
For a reliable
switching signal, the hysteresis is 0.5 mm.
5.10.1 DIGITAL OUT
Whether Pin 4 is to be operated as a point (with a switch point) or as a window (window function) is defined
here.
5.10.2 SWITCH POINT
The switch point is selected in mm using the arrow keys. The point must be within the measuring range.
5.10.3 WINDOW P1
Window point 1 (for the WINDOW mode) is selected in mm using the arrow keys. The point must be within the
measuring range.
The window must be> 2 mm.
5.10.4 WINDOW P2
Window point 2 (for the WINDOW mode) is selected in mm using the arrow keys. The point must be within the
measuring range.
The window must be> 2 mm.
5.10.5 OUTPUT LEVEL
The output can be set to active high or active low here (inverted).
WINDOW POINT 1
0 mm
DIGITAL OUTPUT: Point
DIGITAL OUTPUT: Window
0 mm
SWITCH POINT
mm
WINDOW POINT 2
WINDOW
OUTPUT LEVEL: Active high
OUTPUT LEVEL: Active low
Signal high
Signal low
Signal high
Signal low
Area
minus (-)
Area
plus (+)
Area
minus (-)
Area
plus (+)
Left
Right
Left
Right