en_BA_OxE7
_PosCon3D.docx
10/64
Baumer Electric AG
17.07.2014 14:21/tof V1.01 ANW_81125407
Frauenfeld, Switzerland
2.4 Measurement
2.5 Optional settings
Measuring field limitation
(optional)
The measuring field can be changed via the
FIELD OF VIEW function. This function is
required when there are objects in the
measuring field which should not be detected.
-
AUTO for limitation with a rectangle of
automatic size
-
Separate configuration of the single
points of the field
LIMIT LEFT, LIMIT RIGHT, OFFSET
Switching output
(optional)
The sensor is equipped with a switching output
that can be configured as a point or as a
window via the DIGITAL OUTPUT function.
Let's get started
The sensor continuously outputs the measuring
value in mm to the display and transmits it via
the analog output to the control. Alternatively,
the measuring value can also be retrieved from
the RS485 interface.
4
5a
5b
LIMIT LEFT
LIMIT RIGHT
OFFSET
Left
Right
Left
Right
Point
Window